F-44

F-44

TROUBLESHOOTING & REPAIR

ABNORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

(HIGH CV MODE)

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

OUTPUT CAPACITOR BANK NOT FUNCTIONING

CH1

0 volts

50 volts

5 ms

This is NOT the typical CV output voltage waveform. The capacitor bank is not functioning. Note the “ripple” in the waveform. The capac- itor bank was disconnected to simu- late an open or non-functioning capacitor bank. Each vertical divi- sion represents 50 volts and each horizontal division represents 5 mil- liseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 10-LX

Page 98
Image 98
Lincoln Electric SVM120-A service manual Abnormal Open Circuit Weld Voltage Waveform High CV Mode