MAINTENANCE

 

 

 

TABLE D.1

 

 

 

KUBOTA ENGINE MAINTENANCE SCHEDULE

 

 

 

 

FREQUENCY

MAINTENANCE REQUIRED

 

Daily or Before

 

 

 

Starting Engine

Fill fuel tank.

 

 

Check oil level.

 

 

Check air cleaner for dirty, loose, or damaged parts.

 

 

Check air intake and cooling areas, clean as necessary.

 

Every 50 Hours

Check fuel lines and clamps.

 

Every 100 Hours

Clean air filter element.

 

 

Clean fuel filter.

 

 

Change engine oil.

 

 

Check battery electrolyte level.

 

 

Check fan belt tightness.

 

Every 200 Hours

Check radiator hoses.

 

 

Replace oil filter cartridge.

 

Every 400 Hours

Replace fuel filter element.

 

 

 

 

Refer to your Kubota engine Owner’s Manual for periodic maintenance at 500 hours and beyond.