TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT AC WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

CH1

0 volts

50 volts

5 ms

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 10-LX

Page 101
Image 101