Lincoln Electric SVM120-A service manual Installation, Technical Specifications Ranger 10-LX

Models: SVM120-A

1 133
Download 133 pages 21.1 Kb
Page 8
Image 8

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-2

A-2

INSTALLATION

TECHNICAL SPECIFICATIONS - RANGER 10-LX

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

 

 

Manufacturer

 

Description

 

Speed Displacement

Ignition

 

Capacities

KUBOTA

 

3 cyl.,

 

3600 RPM

52.17 cu. in.

Electric

 

Fuel: 10 gal. (38 l)

DH850B-88

 

liquid-cooled

 

Full load

(855 cc)

 

 

 

 

 

 

diesel

 

 

 

 

 

 

Oil: 3.9 qt. (3.7 l)

 

 

23 HP @

 

3750 RPM

 

 

 

 

 

 

 

3600 RPM

 

High idle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling system:

 

 

 

 

 

 

2150 RPM

 

 

 

 

5.4 qts. (5.1 l)

 

 

 

 

 

 

Low idle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT - WELDER

 

 

 

 

Duty Cycle

 

 

Amps

 

Volts at Rated Amperes

100% Duty Cycle

 

 

250 AC Constant Current

 

 

25

100% Duty Cycle

 

 

250 DC Constant Current

 

 

25

100% Duty Cycle

 

 

250 DC Constant Voltage

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT - WELDER AND GENERATOR

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary Power for

Welding Ranges

Max. Open Circuit Voltage Auxiliary Power(1)

 

Wire Feeders

45- 250 Amps

 

 

 

80 Volts RMS

10000 Continuous Watts

 

42V, 60 Hz, 8 Amps

 

 

 

 

 

@ 3700 RPM

87 Amps @ 115 V

 

 

 

 

 

 

 

 

 

 

43.5 Amps @ 230 V

 

115V, 60 Hz, 8 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

Height

 

 

 

 

Width

Depth

 

 

 

Weight

37.4 in.

 

 

 

 

24.8 in.

60.5 in.

 

 

 

1100 lb.

949 mm

 

 

 

 

629 mm

1529 mm

 

 

 

499 kg

 

 

 

 

 

 

 

 

 

 

 

 

(1)Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

RANGER 10-LX

Page 8
Image 8
Lincoln Electric SVM120-A service manual Installation, Technical Specifications Ranger 10-LX