Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-6

 

F-6

 

TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

No auxiliary power at receptacles –

1. If the machine is equipped with

1. Check the auxiliary power

 

welding output is normal – engine

circuit breakers, check circuit

receptacles and associated

 

runs normally.

breakers. Reset if tripped.

wires for loose or faulty con-

 

 

2. Make sure the output control

nections.

 

 

 

 

 

 

(R1) is set at the maximum

2. Perform the Auxiliary and

 

 

position.

Field Winding Voltage Test.

 

 

3. Check for loose or faulty plug(s)

 

 

 

 

at the power receptacles.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

RANGER 10-LX

Page 60
Image 60
Lincoln Electric SVM120-A service manual Output Problems