B-15

 

 

OPERATION

 

B-15

 

 

 

 

 

 

 

 

 

 

 

 

TABLE B.4 - SIMULTANEOUS WELDING AND AUXILIARY POWER

 

 

 

 

 

 

 

 

 

 

Output Selector

 

Welding

Permissible Power in Watts

Permissible Auxiliary Current

 

 

Setting

 

Output

(Unity Power Factor)

in Amperes

 

 

 

 

 

 

 

@ 115V

@230V

 

 

250

 

250

None

 

 

200

 

200

3000

26

13

 

 

160

 

160

3500

30

15

 

 

120

 

120

5500

48

24

 

 

90

 

90

6500

56

28

 

 

65

 

65

7500

65

32.5

 

 

45

 

45

8500

74

37

 

 

 

CV Low

 

200

7000

60

30

 

 

 

 

 

40

9500

82

41

 

 

 

CV Medium Low

 

250

5500

48

24

 

 

 

 

 

60

8500

74

37

 

 

 

CV Medium High

 

250

3500

30

15

 

 

 

 

 

80

7000

60

30

 

 

 

CV High

 

250

1500

13

6.5

 

 

 

 

 

100

6000

52

26

 

 

 

 

 

 

 

 

 

 