F-15

F-15

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

Output control on welder not func-

1. Make sure the Remote switch

1.

Check the Output Control (R1).

tioning.

(S7) is in the “MACHINE CON-

 

Normal resistance is 10,000

 

TROL” position.

 

ohms. Replace if defective.

 

2. The Output Control (R1) may be

2.

Check the Remote switch (S7)

 

defective.

 

and associated wiring.

See

 

 

 

Wiring Diagram (leads #75, #76,

 

 

 

and #77).

 

 

 

3. The control board may

be

 

 

 

faulty. Replace.

 

 

 

 

 

Remote output control not func-

1. Make sure the Remote switch

1.

Check the Remote switch (S7)

tioning.

(S7) is in the “REMOTE” posi-

 

and associated wiring.

See

 

tion.

 

Wiring Diagram (leads #75, #76,

 

2. The remote control unit may be

 

and #77).

 

 

 

 

 

 

faulty. Repair or replace.

2. The RF bypass board may be

 

 

 

defective. Check or replace.

 

 

 

 

 