Lincoln Electric SVM120-A service manual Typical AC Weld Output Voltage Waveform

Models: SVM120-A

1 133
Download 133 pages 21.1 Kb
Page 96
Image 96

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-42

F-42

TROUBLESHOOTING & REPAIR

TYPICAL AC WELD OUTPUT VOLTAGE WAVEFORM

MACHINE LOADED

CH1

0 volts

20 volts

5 ms

MACHINE LOADED TO 250 AMPS AT 25VDC

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time. The machine was loaded with a resistance grid bank.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 10-LX

Page 96
Image 96
Lincoln Electric SVM120-A service manual Typical AC Weld Output Voltage Waveform, Machine Loaded to 250 Amps AT 25VDC