Lincoln Electric SVM120-A service manual Normal Open Circuit DC Weld Voltage Waveform

Models: SVM120-A

1 133
Download 133 pages 21.1 Kb
Page 100
Image 100

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-46

F-46

TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

CH1

0 volts

50V

5 ms

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 10-LX

Page 100
Image 100
Lincoln Electric SVM120-A service manual Normal Open Circuit DC Weld Voltage Waveform