Lincoln Electric SVM120-A Electrical Output Connections, Muffler Relocation, Spark Arrester

Models: SVM120-A

1 133
Download 133 pages 21.1 Kb
Page 11
Image 11

to Section TOC

to Master TOC

A-5

A-5

INSTALLATION

FIGURE A.1 - RANGER 10-LX OUTPUT CONNECTIONS

2

1

5

1.115/230 VOLT, 50 AMP RECEPTACLE

2.115 VOLT, 20 AMP RECEPTACLES (2)

3.WELD OUTPUT TERMINALS (2)

4.GROUND STUD (LOCATION)

5.CIRCUIT BREAKERS (CSA machines only)

43

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

MUFFLER RELOCATION

WARNING

Shut off the machine and allow the muffler to cool before touching the muffler.

The RANGER 10-LX is shipped with the exhaust directed toward the rear. It can be changed to the right side by loosening the clamp that holds the exhaust deflector in place and rotating the deflector to the desired direction.

SPARK ARRESTER

Diesel engine mufflers may emit sparks when the engine is running. Some federal, state, or local laws require spark arresters in locations where unarrested sparks could present a fire hazard.

Standard mufflers and deflectors (like the ones includ- ed with the RANGER 10-LX) do not act as spark arresters. When local laws require it, a spark arrester must be installed on the machine and properly main- tained. An optional spark arrester kit (K903-1) is avail- able for your RANGER 10-LX. See the Accessories section of this manual for more information.

CAUTION

An incorrect spark arrester may lead to damage to the engine or reduce performance.

ELECTRICAL OUTPUT

CONNECTIONS

See Figure A.1 for the location of the 115 and 230 volt receptacles, weld output terminals, circuit breakers and ground stud.

RANGER 10-LX

Page 11
Image 11