F-16

F-16

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The wire feeder does not work

1. Check circuit breaker CB2.

1.

Check for the presence of

when connected to the welder

Reset if tripped.

 

115VAC at leads #31A and #32.

amphenol.

2. The wire feeder control cable

 

See Wiring Diagram.

 

 

 

 

may be faulty. Check or

2.

Check for the presence of

 

replace.

 

42VAC at leads #31B to #42.

 

3. The wire feeder may be faulty.

 

See Wiring Diagram.

 

 

 

 

Check or replace.

3.

If any of the above voltages are

 

 

 

missing or low, then check the

 

 

 

circuit breaker CB2 for proper

 

 

 

operation.

 

 

4.

The RF bypass board may be

 

 

 

faulty. Check or replace.

 

 

5.

Perform the Auxiliary and Field

 

 

 

Winding Test.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.