Lucent Technologies 1079984G3 manual Frl Npa

Models: 1079984G3

1 130
Download 130 pages 32.89 Kb
Page 25
Image 25

Feature Descriptions

change route-pattern X (X is the routing pattern)

On this form, assign a routing pattern for the emergency service access code.

In this first example, Preference 1 of Pattern 5 is used when guests

dial 9911 (9 for the ARS access code, and 911 for the emergency service agency).

change

route-pattern

5

 

Page

1 of 1

 

 

 

 

 

 

 

Pattern Number: 5

 

 

Grp.

 

FRL

NPA

Pfx Hop Toll No. Del

Inserted

IXC

 

No.

 

 

 

Mrk

Lmt List Digits

Digits

 

1:

5

 

 

0

 

 

 

 

 

 

2:

 

 

 

 

 

 

 

 

 

 

3:

 

 

 

 

 

 

 

 

 

 

4:

 

 

 

 

 

 

 

 

 

 

5:

 

 

 

 

 

 

 

 

 

 

6:

 

 

 

 

 

 

 

 

 

 

 

 

BCC VALUE

 

TSC

CA-TSC

ITC

BCIE Service/Feature

Numbering

 

0

1

2

3 4

W

 

Request

 

 

Format

1: y y

y y y

n

n

 

rest

 

 

2: y y

y y y

n

n

 

rest

 

 

3: y y

y y y

n

n

 

rest

 

 

4: y y

y y y

n

n

 

rest

 

 

5: y y

y y y

n

n

 

rest

 

 

6: y y

y y y

n

n

 

rest

 

 

Issue 1 April 1997 19

Page 25
Image 25