Call Coverage

Administration

change system-parameters hospitality

On Page 1 of this form, enter an assignment in the Client Room Cov- erage Path Configuration field. If your server has no PMS or the guest room coverage path is not controlled by the PMS, put act-nopmsin this field. If the guest room coverage path is controlled by the PMS, put act-pmsin this field. The PMS vendor should be consulted concerning this setting.

On Page 1 of this form, enter an assignment in the Default Coverage Path for Client Rooms field. This field defines the coverage path number set for a guest room when the server receives a check out mes- sage in the Transparent Mode or the ASCII Mode. The default coverage path is used when the PMS cannot function in the Transparent Mode or ASCII Mode, or when the room is unoccupied. This field may be left blank to indicate no coverage path.

The default coverage path is also used when translations are being saved on the server. This path is used for each station with a “client room” COS.

change station XXXX (XXXX is the extension number of a voice terminal)

Enter a coverage path number in the Coverage Path field.

Use this form to add send-callsand go-to-cvrbuttons on the office staff voice terminals.

change coverage path X (X is the coverage path number)

Use this form to administer the coverage path criteria for your guest room telephones and your hotel staff voice terminals.

Required Hardware

There is no special hardware required for this feature.