Feature Descriptions
Administration
change system-parameters hospitality
■On Page 1 of this form, enter y in the Forward PMS Message to Intuity Lodging field and transparent in the PMS Protocol Mode field.
change communication-interface processor-channels
■On Page 4 of this form, administer processor interface channel 59 to the audix application with the
Required Hardware
There is no special hardware required for this feature. However, if you upgrade your existing GuestWorks server with this new feature, you must disconnect the voice messaging link between the Lucent INTUITY and the PMS.
Required Software
To take advantage of this new feature, the PMS software may need to be upgraded to be compatible. Contact your PMS vendor and request that they ver- ify that their software complies with the DEFINITY Enterprise Communications Server (ECS), GuestWorks server, and System 75 PBX Property Management System Interface Specifications,
The Lucent INTUITY software must be at least Issue 1.1 and the GuestWorks server must be at least Issue 2.0.
Issue 1 April 1997 93