Emergency Access to the Attendant

Administration

change system-parameters feature

On Page 3 of this form, enter a time value (1-3000 seconds) in the Time before Off-hook Alert field. This is the number of seconds before an emergency call goes to the attendant. This interval does not include the 10 seconds of dial tone a guest receives after going off-hook. The recommended value for this field is 10.

On Page 3 of this form, enter an extension number in the Emergency Access Redirection Extension field. This is a backup extension for receiving emergency calls destined for the attendant console.

On Page 3 of this form, enter a value (0-25) in the Number of Emer- gency Calls Allowed in Attendant Queue field. This deter- mines the number of emergency calls allowed in the attendant queue before calls are redirected to an emergency backup extension.

change feature-access-codes

On Page 1 of this form, add a feature access code for the Emergency Access to Attendant feature.

change cos

For all classes of service where you want the Emergency Access To Attendant feature available when the phone is left off-hook, enter y in the

Off-hook Alert field.

NOTE:

Some guests may not use the Do Not Disturb feature and simply take their guest room telephone off-hook when they do not want to be dis- turbed. If you have enabled the off-hook emergency alerting option, the front desk may be deluged by “false” emergency calls. You may want to limit access to the Emergency Access to Attendant feature by requiring guests to use the feature access code.