NEC 5020M-16, NX7700i SP Command List, The following tables contain SP command lists by category

Models: 5020M-16 NX7700i

1 149
Download 149 pages 48.62 Kb
Page 48
Image 48

Base Module

2.4.5.4.SP Command List

The following tables contain SP command lists by category:

System Control

CMD

command name

function

iSP

state

 

 

 

DF

Shut down System power

The iSP turns off the DC power of the

 

specified partition without notifying the

m

(override)

 

SW (OS) even if it is running.

 

 

 

 

 

 

If the specified partition is in S0 state,

 

DN

Shut down System power

the iSP only generates the SCI

m

(POWBTN). Otherwise, the iSP turns

 

 

 

 

 

off the DC power directly.

 

 

 

The iSP generates the INIT signal to

 

DP

System Dump

the specified partition. SW (OS) will

m

 

 

enter its dump routine.

 

 

 

The iSP turns off the DC power of the

 

 

 

specified partition without notifying the

 

PC

Power Cycle

SW (OS) even if it is running, turns on

m

 

 

the DC power, initializes HW and

 

 

 

hands off the control to the BIOS.

 

 

 

The iSP initializes the specified

 

RS

Cold Reset System

partition without notifying the SW (OS)

m

 

 

even if it is running.

 

 

 

The iSP turns on the DC power of the

 

UB

Bring up BIOS

specified partition and initializes HW

m

 

 

and hands off the control to the BIOS.

 

 

 

The iSP turns on the DC power of the

 

 

 

specified partition and initializes HW

 

UP

Bring up System

and hands off the control to the BIOS.

m

 

 

The BIOS will boot the Operating

 

 

 

System.

 

“m”: Commands can be executed only on the master iSP.

2-29

855-900549

Page 48
Image 48
NEC 5020M-16 SP Command List, The following tables contain SP command lists by category, System Control, Base Module