NEC NX7700i, 5020M-16 operation manual Description DescriptionDescription No

Models: 5020M-16 NX7700i

1 149
Download 149 pages 48.62 Kb
Page 107
Image 107

Base Module

ERROR: cmossave/cmos2.bin does not exist. Enter partition number? (0-7/CR=exit) : checking downloaded file.

passed.

restoring CMOS/NvRAM...

completed.

You need to reset the target partition.

Enter partition number? (0-7/CR=exit) : <ENTER> SR command terminated.

(k)

(l)

(m)

(Description)

DescriptionDescription

No.

(a)Enter the target partition No., and then choose “s” to start saving.

(b)Shows data reading from the specified partition in progress.

(c)If a read error occurred, an error message appears and the screen returns to the partition No. prompt.

Enter the save destination FTP Server information.

[Account, password, and file path name are all case-sensitive.]

(d)Up to 20 characters are usable for an account, up to 78 characters for a password, and up to 100 characters for a file path. If any of them exceeds these limits, reconfigure the FTP Server as needed.

(e)If you are sure that the server information you entered is correct, enter “y.”

(f)Shows data saving to the FTP Server in progress.

(h)Shows an example of restore procedure.

(i)Enter FTP Server information for confirmation.

(j)Shows data restoration from the FTP Server in progress.

(k)If data restoration failed, an error message appears, and the screen returns to the partition No. prompt.

(l)Shows data restoration to the specified partition in progress.

(m)Pressing <ENTER> quits the SR command.

855-900549

2-88

Page 107
Image 107
NEC NX7700i, 5020M-16 operation manual Description DescriptionDescription No