Base Module
cmd | arg1 | arg2 | arg3 | arg4 | Description |
| mmxxy | - | - | - | Show the detailed configuration of the ROW |
|
|
|
|
| under the MMX specified by xy, and in the |
|
|
|
|
| case of the 32Way(H) model, show detailed |
|
|
|
|
| configuration of the DIR. |
|
|
|
|
| x is the physical CELL number where the |
|
|
|
|
| MMX is installed |
|
|
|
|
| y is the MMX number within the CELL |
| tagxs | - | - | - | Show the detailed configuration of the TAG |
|
|
|
|
| for the 32Way(B)/8Way/ISPF models. This |
|
|
|
|
| argument is invalid for the 32Way(H) model. |
|
|
|
|
| x is the physical CELL number where the |
|
|
|
|
| TAG is installed |
|
|
|
|
| s is either ’e’ (EVEN side) or ’o’ (ODD side). |
| xbxcx | - | - | - | Show the XBX Card configuration and XBX |
|
|
|
|
| LSI configuration on that card. |
|
|
|
|
| x is a physical XBX Card number |
| xbxxy | - | - | - | Show the XBX configuration. |
|
|
|
|
| x is an XBX Card number |
|
|
|
|
| y specifies an XBX number on the XBX Card |
|
|
|
|
| |
| pcibx | - | - | - | Show the PCI Bay (IOX) configuration. |
| ioxx |
|
|
| x is the DGI/I2C cable port number |
|
|
|
|
| connects iSP to PCI Bay. |
| pcix | - | - | - | Show the configurations and information of |
|
|
|
|
| the PCI Cards that are under the PXH within |
|
|
|
|
| the PCI Bay. |
|
|
|
|
| x is the DGI/I2C cable port number |
|
|
|
|
| connects iSP to PCI Bay. |
| cpcix | - | - | - | Show the configurations and information of |
|
|
|
|
| the PCI Cards on the Core Card within the |
|
|
|
|
| PCI Bay. |
|
|
|
|
| x is the DGI/I2C cable port number |
|
|
|
|
| connects iSP to PCI Bay. |
| pbayx | - | - | - | Show the Power Bay configuration. |
|
|
|
|
| x is a Power Bay number. The allowable |
|
|
|
|
| range of x is as follows: |
|
|
|
|
| For 32Way: |
|
|
|
|
| 0, 1: Power Bay numbers within the Main |
|
|
|
|
| Cabinet |
|
|
|
|
| 2, 3: Power Bay numbers within the |
|
|
|
|
| Expansion Cabinet |
|
|
|
|
| For 8Way: |
|
|
|
|
| 0: Power Bay No. inside the chassis |
|
|
|
|
| 1: Power Bay No. outside the chassis |
|
|
|
|
| For ISPF: |
|
|
|
|
| 0: Power Bay No. inside the chassis |
attach
-
- | - | - |
|
|
|
Use this command to attach partition numbers to CELL or IOX Cards.
If no argument is specified or an argument has an error, the attach command help opens.
This command is not valid while the partition is booting up, shutting down, or handling an error.