Base Module

cmd

arg1

arg2

arg3

arg4

Description

 

mmxxy

-

-

-

Show the detailed configuration of the ROW

 

 

 

 

 

under the MMX specified by xy, and in the

 

 

 

 

 

case of the 32Way(H) model, show detailed

 

 

 

 

 

configuration of the DIR.

 

 

 

 

 

x is the physical CELL number where the

 

 

 

 

 

MMX is installed (0-7).

 

 

 

 

 

y is the MMX number within the CELL (0-3).

 

tagxs

-

-

-

Show the detailed configuration of the TAG

 

 

 

 

 

for the 32Way(B)/8Way/ISPF models. This

 

 

 

 

 

argument is invalid for the 32Way(H) model.

 

 

 

 

 

x is the physical CELL number where the

 

 

 

 

 

TAG is installed (0-7).

 

 

 

 

 

s is either ’e’ (EVEN side) or ’o’ (ODD side).

 

xbxcx

-

-

-

Show the XBX Card configuration and XBX

 

 

 

 

 

LSI configuration on that card.

 

 

 

 

 

x is a physical XBX Card number (0-3).

 

xbxxy

-

-

-

Show the XBX configuration.

 

 

 

 

 

x is an XBX Card number (0-3).

 

 

 

 

 

y specifies an XBX number on the XBX Card

 

 

 

 

 

(0-1).

 

pcibx

-

-

-

Show the PCI Bay (IOX) configuration.

 

ioxx

 

 

 

x is the DGI/I2C cable port number (0-7) that

 

 

 

 

 

connects iSP to PCI Bay.

 

pcix

-

-

-

Show the configurations and information of

 

 

 

 

 

the PCI Cards that are under the PXH within

 

 

 

 

 

the PCI Bay.

 

 

 

 

 

x is the DGI/I2C cable port number (0-7) that

 

 

 

 

 

connects iSP to PCI Bay.

 

cpcix

-

-

-

Show the configurations and information of

 

 

 

 

 

the PCI Cards on the Core Card within the

 

 

 

 

 

PCI Bay.

 

 

 

 

 

x is the DGI/I2C cable port number (0-7) that

 

 

 

 

 

connects iSP to PCI Bay.

 

pbayx

-

-

-

Show the Power Bay configuration.

 

 

 

 

 

x is a Power Bay number. The allowable

 

 

 

 

 

range of x is as follows:

 

 

 

 

 

For 32Way:

 

 

 

 

 

0, 1: Power Bay numbers within the Main

 

 

 

 

 

Cabinet

 

 

 

 

 

2, 3: Power Bay numbers within the

 

 

 

 

 

Expansion Cabinet

 

 

 

 

 

For 8Way:

 

 

 

 

 

0: Power Bay No. inside the chassis

 

 

 

 

 

1: Power Bay No. outside the chassis

 

 

 

 

 

For ISPF:

 

 

 

 

 

0: Power Bay No. inside the chassis

attach

-

-

-

-

 

 

 

Use this command to attach partition numbers to CELL or IOX Cards.

If no argument is specified or an argument has an error, the attach command help opens.

This command is not valid while the partition is booting up, shutting down, or handling an error.

855-900549

2-46

Page 65
Image 65
NEC NX7700i, 5020M-16 operation manual Base Module