Base Module

2.4.6.10. PC (Power Cycle)

m

b

u

X

 

 

*The command is executable to the active partition (after automatic system boot/UP command execution).

Function:

This command is used to cycle system power (system reboot after system DC power off).

Note that this command shuts off system power without regard to the current OS or BIOS status or notifying nothing to the OS or BIOS.

Partitions that are already off or those being shut down are not the target of this command.

(Screen Example)

 

 

Description

 

 

No.

iSPyz:--->

pc<ENTER>

 

CAUTION: System power will be turned off without any notice to the softwares

 

even if they are running.

 

Enter partition number (0-7/all/CR=exit) : 0<ENTER>

(a)

Execute OK? (y/[n]) y<ENTER>

(b)

PC command was accepted. System power of all partitions will be turned off soon

(c)

and then will be turned on.

 

mm/dd/yyyy

HH:MM:SS 0------- System shutdown started. (SPFW:Rxx.xx)

 

:

 

 

mm/dd/yyyy

HH:MM:SS 0------- System shutdown completed. (SPFW:Rxx.xx)

 

mm/dd/yyyy

HH:MM:SS 0------- System initialization started. (SPFW:Rxx.xx)

(d)

:

 

 

 

mm/dd/yyyy

HH:MM:SS 0------- System initialization completed. (SPFW:Rxx.xx)

 

[iSP0m:INFO.2129] partition 0 : handed off the control to BIOS.

 

 

(DIPSW = 00000000)

 

 

 

 

(Description)

 

Description

Description

No.

 

(a)Prompts a partition number.

If “all” is specified, all the existing partitions are the target of this command.

(b)Enter y at this confirmation message if you are sure to continue command execution.

(c)A “PC command accepted” message appears.

The actual processing progresses in the background.

(d)Shows the progress in the background.

855-900549

2-74

Page 93
Image 93
NEC NX7700i, 5020M-16 operation manual PC Power Cycle, Hhmmss 0------- System shutdown completed. SPFWRxx.xx