NEC 5020M-16 Note, Possible Events including operator entries and System Responses, Base Module

Models: 5020M-16 NX7700i

1 149
Download 149 pages 48.62 Kb
Page 40
Image 40

Base Module

Possible Events (including operator entries) and System Responses

Event

System Response

Login account or password was wrong.

The login prompt reappears after the message

 

“incorrect” comes on.

Login account or password rejected 3

The console is disconnected.

times consecutively.

 

No operations made for 5 minutes on the

The console is disconnected after the message

login account or password prompt screen.

“timeout” appears.

A letter not specified in the menu was

The menu reopens.

entered.

 

No operation made for 5 minutes on the

The console is disconnected after the message

Menu screen.

“timeout” appears.

The menu became invalid after iSP

The invalid menu or prompt is not identified

master assignment has been changed.

immediately.

 

If you make a selection in the invalid menu, that

 

selection is rejected and a new menu opens.

A value from 0 to 7 selected.

OS (BIOS) Serial Console Redirection is chosen.

(valid only on the master iSP)

 

S selected.

SP Command Console is chosen.

(valid regardless of master/backup

 

assignment)

 

V selected.

Virtual SOP is chosen.

(valid only on the master iSP)

 

E selected.

The current console connection is disconnected.

DISCONNECTALL selected.

All TCP connections to the iSP other than the

 

current console connection are disconnected and

 

the screen is forcibly returned to the Main Menu

 

in case of serial connection console.

 

This emergency action might be needed if

 

console operation is prohibited when actually

 

disconnected TCP connections remain alive

 

under the iSP management due to client’s illegal

 

access.

The number of simultaneous connections

The screen returns to the Main Menu after

allowable for the selected mode was

showing a message “N connections to the

exceeded.

selected mode are already established. Try it

 

later.”

2.4.2.Note

While in serial or OS console connection, characters that are shown on the console screen may be disturbed due to redirection made in a half way of ESC sequence.