Description

 

disable

-

-

-

-

Use this command to manually “DISABLE”

 

 

 

 

 

 

the components that are currently enabled.

 

 

 

 

 

 

If no argument is specified or an argument

 

 

 

 

 

 

has an error, the disable command help

 

 

 

 

 

 

opens.

 

 

 

 

 

 

Online components are unable to be

 

 

 

 

 

 

disabled.

 

 

 

 

 

 

It is not allowed to disable the CELL Card,

 

 

 

 

 

 

XBX Card, PCI Bay, and their

 

 

 

 

 

 

subcomponents when any of the partitions

 

 

 

 

 

 

within the system is booting up, shutting

 

 

 

 

 

 

down, or handling an error.

 

 

<arg1>

<arg2>

-

-

<arg1> and <arg2> are the same as those

 

 

 

 

 

 

for the enable command.

 

 

 

 

 

 

Argument “all” is not allowed for this

 

 

 

 

 

 

command.

 

online

-

-

-

-

This command is currently not supported.

 

 

 

 

 

 

This command can be used to dynamically

 

 

 

 

 

 

connect currently offline components (CELL,

 

 

 

 

 

 

XBX Card, and PCI Bay) to the system while

 

 

 

 

 

 

the OS is running. It remains invalid while

 

 

 

 

 

 

any of the partitions within the system is

 

 

 

 

 

 

booting up, shutting down, or handling an

 

 

 

 

 

 

error.

 

 

 

 

 

 

The CELL and PCI Bay are functional only if

 

 

 

 

 

 

they are used in online conjunction with the

 

 

 

 

 

 

OS that supports this command function.

 

 

 

 

 

 

If no argument is specified or an argument

 

 

 

 

 

 

has an error, the online command help

 

 

 

 

 

 

opens.

 

 

 

 

 

 

This command is supported on the

 

 

 

 

 

 

32Way(B), 8Way, and ISPF models. It is not

 

 

 

 

 

 

supported on the 32Way(H) model.

 

 

cellx

-

-

-

Connect CELL Cards to the partition to which

 

 

 

 

 

 

they belong.

 

 

 

 

 

 

A vacant partition to which no CELL or IOX

 

 

 

 

 

 

belongs is needed.

 

 

 

 

 

 

This command is supported on the 32Way(B)

 

 

 

 

 

 

and 8Way models.

 

 

xbxcx

-

-

-

Connect XBX Cards to the system.

 

 

 

 

 

 

On the 32Way(B) model, XBX Cards need

 

 

 

 

 

 

be connected to the system in pairs: i.e. XBX

 

 

 

 

 

 

Cards 0 and 2 or 1 and 3. A single XBX Card

 

 

 

 

 

 

alone is not accepted.

 

 

 

 

 

 

The XBX Card is not connectable to the

 

 

 

 

 

 

8Way model.

 

 

xbxc0

portx

 

 

Connect inter-XBX external interface ports to

 

 

 

 

 

 

the system, to which cabinets are connected.

 

 

 

 

 

 

x: XBX port number (4-5)

 

 

 

 

 

 

This command is supported on the ISPF

 

 

 

 

 

 

system. It is valid when the operating

 

 

 

 

 

 

systems are running (ACPI S0 State) on both

 

 

 

 

 

 

systems.