Base Module
cmd | arg1 | arg2 | arg3 | arg4 | Description |
| memdx | - | - | - | This command is only valid to the 32Way |
|
|
|
|
| model. |
|
|
|
|
| Use it to add MMX |
|
|
|
|
| memory daughter card. The DIMM capacity |
|
|
|
|
| is automatically read when it is being |
|
|
|
|
| initialized. |
|
|
|
|
| x is the physical number of the CELL Card |
|
|
|
|
| |
| pcibx | de | [core] | - | Add PCI Bays. |
|
|
|
|
| x is a DGI/I2C port number on the iSP side |
|
|
|
|
| |
|
|
|
|
| Use arg2 to specify the type of the PCI Bay |
|
|
|
|
| (mandatory). Specify “d” for |
|
|
|
|
| “e” for |
|
|
|
|
| Specify “core” for arg3 if Core Cards (GXB) |
|
|
|
|
| are installed. |
|
|
|
|
| If the type of the PCI Bay (PCID/PCIE) or the |
|
|
|
|
| presence of the Core Card has been |
|
|
|
|
| changed, the SP will know that change from |
|
|
|
|
| the revision information for that PCI Bay. |
delete | - | - | - | - | Use this command to delete components |
|
|
|
|
| from iSP management. If physically removed |
|
|
|
|
| components are left under iSP management, |
|
|
|
|
| they will be handled as an “INVISIBLE” error |
|
|
|
|
| indefinitely. |
|
|
|
|
| If no argument is specified or an argument |
|
|
|
|
| has an error, the delete command help |
|
|
|
|
| opens. |
|
|
|
|
| Components in |
|
|
|
|
| be deleted (with the exception of the CLK |
|
|
|
|
| and DPS). |
|
|
|
|
| The CELL Card, XBX Card, PCI Bay, or their |
|
|
|
|
| subcomponents is unable to be deleted if |
|
|
|
|
| any of the partitions within the system is |
|
|
|
|
| booting up, shutting down, or handling an |
|
|
|
|
| error. |
| <arg1> | - | - | - | <arg1> is identical to that for the add |
|
|
|
|
| command. |
enable | - | - | - | - | Use this command to enable the |
|
|
|
|
| components that are currently “DISABLED.” |
|
|
|
|
| If no argument is specified or an argument |
|
|
|
|
| has an error, the enable command help |
|
|
|
|
| opens. |
|
|
|
|
| This command is valid only if the partition to |
|
|
|
|
| which the pertinent components belong is |
|
|
|
|
| not active. |
|
|
|
|
| The CELL Card, XBX Card, PCIX, and their |
|
|
|
|
| subcomponents can be enabled unless any |
|
|
|
|
| of the partitions within the system is booting |
|
|
|
|
| up, shutting down, or handling an error. |
|
|
|
|
| The Power Bay can be enabled only if none |
|
|
|
|
| of the partitions within the system is active. |