NEC 5020M-16, NX7700i operation manual Base Module

Models: 5020M-16 NX7700i

1 149
Download 149 pages 48.62 Kb
Page 70
Image 70

Base Module

cmd

arg1

arg2

 

arg3

arg4

 

Description

 

pbayx

-

-

 

-

Enable the Power Bay.

 

 

 

 

 

 

x is a Power Bay number. The allowable

 

 

 

 

 

 

value of x is as follows:

 

 

 

 

 

 

For 32Way:

 

 

 

 

 

 

0, 1: Power Bay numbers within the Main

 

 

 

 

 

 

 

Cabinet

 

 

 

 

 

 

2, 3: Power Bay numbers within the

 

 

 

 

 

 

 

Expansion Cabinet

 

 

 

 

 

 

For 8Way:

 

 

 

 

 

 

0:

Power Bay number inside the chassis

 

 

 

 

 

 

1:

Power Bay number outside the chassis

 

 

 

 

 

 

For ISPF:

 

 

 

 

 

 

0:

Power Bay number inside the chassis

 

clkx

-

-

 

-

Enable the CLK.

 

 

 

 

 

 

x is a CLK number (0 or 1).

 

 

 

 

 

 

The CLK is installed only in the 32Way

 

 

 

 

 

 

model.

 

xbxcx

[all]

-

 

-

Enable the XBX Card.

 

 

 

 

 

 

x is an XBX Card number (0-3).

 

 

 

 

 

 

If arg2 is omitted, only the XBX Card is

 

 

 

 

 

 

enabled, with its subcomponents left

 

 

 

 

 

 

disabled.

 

 

 

 

 

 

If “all” is specified for arg2, XBX Card is

 

 

 

 

 

 

enabled including all of its subcomponents.

 

xbxxy

[all]

-

 

-

Enable the XBX LSI.

 

 

 

 

 

 

x is an XBX Card number (0-3).

 

 

 

 

 

 

y is an XBX LSI number (0-1) on an XBX

 

 

 

 

 

 

Card.

 

 

 

 

 

 

If arg2 is omitted, only the XBX Card is

 

 

 

 

 

 

enabled, with its subcomponents left

 

 

 

 

 

 

disabled.

 

 

 

 

 

 

If “all” is specified for arg2, the XBX Card is

 

 

 

 

 

 

enabled including all of its subcomponents.

 

 

 

 

 

 

 

 

cellx

[all]

-

 

-

Enable the CELL Card.

 

 

 

 

 

 

x is a physical CELL number (0-7).

 

 

 

 

 

 

If arg2 is omitted, only the CELL Card is

 

 

 

 

 

 

enabled, with its subcomponents left

 

 

 

 

 

 

disabled. In this case, console operation will

 

 

 

 

 

 

be rejected if essential components are

 

 

 

 

 

 

disabled.

 

 

 

 

 

 

If “all” is specified for arg2, the CELL Card is

 

 

 

 

 

 

enabled including all of its subcomponents.

 

cnxxy

-

-

 

-

Enable the CNX LSI.

 

 

 

 

 

 

x is a physical CELL number (0-7).

 

 

 

 

 

 

y is a CNX number (0-1) within a CELL.

 

 

 

 

 

 

CNX1 exists only in the 32Way(H) model.

 

procxy

-

-

 

-

Enable the Processor.

 

 

 

 

 

 

x is a physical CELL number (0-7).

 

 

 

 

 

 

y is a Processor number (0-3) within the

 

 

 

 

 

 

CELL.

 

mmxxy

[all]

-

 

-

Enable the MMX.

 

 

 

 

 

 

x is a physical CELL number (0-7).

 

 

 

 

 

 

y is an MMX number (0-3) within the CELL.

 

 

 

 

 

 

If arg2 is omitted, only the MMX is enabled,

 

 

 

 

 

 

with its subcomponents left disabled.

 

 

 

 

 

 

If “all” is specified for arg2, the MMX is

 

 

 

 

 

 

enabled including all of its subcomponents.

2-51

855-900549

Page 70
Image 70
NEC 5020M-16, NX7700i operation manual Base Module