Base Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cmd

arg1

 

arg2

arg3

arg4

Description

 

 

cellx

n

 

m

-

Attach the CELL Card having physical CELL

 

 

 

 

 

 

 

number x to partition number n, using logical

 

 

 

 

 

 

 

CELL number m (which is visible to the

 

 

 

 

 

 

 

software or BIOS).

 

 

 

 

 

 

 

This command may also be used to change

 

 

 

 

 

 

 

a logical CELL number for an already

 

 

 

 

 

 

 

attached CELL.

 

 

 

 

 

 

 

A logical CELL number must be unique to

 

 

 

 

 

 

 

every 8 CELL Cards.

 

 

 

 

 

 

 

The logical CELL number of an online CELL

 

 

 

 

 

 

 

Card is unable to be altered.

 

 

ioxx

n

 

m

[ps]

Attach the IOX Card having physical IOX

 

 

 

 

 

 

 

number x to partition number n, using logical

 

 

 

 

 

 

 

IOX number m (which is visible to the

 

 

 

 

 

 

 

software or BIOS).

 

 

 

 

 

 

 

Specify p for arg4 if the PCI Bay with BIO is

 

 

 

 

 

 

 

to use that BIO. Specify s for arg4 if the PCI

 

 

 

 

 

 

 

Bay having duplicated BIOs is to use the

 

 

 

 

 

 

 

secondary BIO.

 

 

 

 

 

 

 

This command may also be used to change

 

 

 

 

 

 

 

a logical IOX number for an already attached

 

 

 

 

 

 

 

IOX.

 

 

 

 

 

 

 

A logical IOX number must be unique within

 

 

 

 

 

 

 

a partition.

 

 

 

 

 

 

 

The logical IOX number of an online IOX

 

 

 

 

 

 

 

Card cannot be altered.

 

detach

-

-

 

-

-

Use this command to detach partition

 

 

 

 

 

 

 

numbers from CELL or IOX Cards.

 

 

 

 

 

 

 

If no argument is specified or an argument

 

 

 

 

 

 

 

has an error, the detach command help

 

 

 

 

 

 

 

opens.

 

 

 

 

 

 

 

Online components are unable to be

 

 

 

 

 

 

 

detached.

 

 

 

 

 

 

 

It is not allowed to detach components either

 

 

 

 

 

 

 

when the partition is booting up, shutting

 

 

 

 

 

 

 

down, or handing an error.

 

 

cellx

-

 

-

-

Detach the CELL Card with physical CELL

 

 

 

 

 

 

 

number x from the partition to which it is

 

 

 

 

 

 

 

currently attached.

 

 

ioxx

-

 

-

-

Detach the IOX Card with physical IOX

 

 

 

 

 

 

 

number x from the partition to which it is

 

 

 

 

 

 

 

currently attached.

 

 

partx

-

 

-

-

Detach all the CELL and IOX Cards from the

 

 

 

 

 

 

 

partitions to which they are currently

 

 

 

 

 

 

 

attached.

 

 

 

 

 

 

 

x: Partition number