24Chapter 3 Hardware Troubleshooting

BRIM LEDs

The BRIM has one additional LED beside each RJ-48C jack. These LEDs are on when the ISDN line is active. The figure BRIM LEDs on page 24 shows the location of the LEDs on a BRIM.

Figure 4 BRIM LEDs

Power LED

Status LED

For more information on the power and status LED functions, see Media bay module LEDs (expansion units only) on page 21.

Check the wiring connections

After you check the power source and the LEDs, begin to check the wiring. Check the connections between the following components:

the expansion unit and the main unit

the main unit and to the MBMs—make sure that the cables are properly seated and are connected to the correct ports

the power supply and the AC power outlet

if you are using a UPS, check the connection from:

the USB port on the BCM450 to the USB port on the UPC

the UPS and the electrical outlet

the connection from the power supply to both the UPS and the BCM450 main unit

the lines and extensions connected through the RJ-21 telephony connector

the auxiliary equipment—connections at the auxiliary terminal block, or at the patch panel

Verify the keycodes

If a specific feature is not functioning, verify that the feature is included in your installed keycodes. This section provides procedure for verifying the installed keycodes using either Element Manager or Telset. For more detailed information about retrieving and entering the keycode for your system, see the Keycode Installation Guide (NN40010-301).

To verify the keycodes using Element Manager

1In the Task Navigation Panel, select the Configuration tab.