Chapter 4 Software Troubleshooting 41

Figure 10 Properties details panel

Table 8 on page 41 defines the fields on this panel and indicates the lines.

Table 8 Properties line settings (Sheet 1 of 2)

Attribute

Value

Description

 

 

 

Legend: Loop = analog/digital loop; GS = ground start; DID = DID; E&M = E&M; BRI = BRI; DPNSS

= DPNSS; VoIP = VoIP; TL = Target. Note: PRI fields are all included under the main table.

Trunk mode

Loop

 

 

 

 

 

 

 

 

 

Unspr

 

Define whether disconnect supervision, also referred to as loop

 

Supervised

supervision, releases an external line when an open switch

 

interval (OSI) is detected during a call on that line. You must set

 

*Earth calling

 

this to Supervised if a loop trunk has its Answer mode set to

 

*Loop guarded

 

Auto or if you enable Answer with DISA. Disconnect

 

*Loop unguarded

supervision is also required to conference two external callers.

 

**ROE, ROI

The line must be equipped with disconnect supervision from the

 

central office for the Supervised option to work.

 

 

 

 

 

 

 

 

* These listing only appear for UK analog lines.

 

 

 

 

** These appear only for Australia.

 

 

 

 

 

 

 

 

 

 

Dial mode

Loop

 

GS

DID

E&M

 

 

 

 

 

Pulse

 

Specify whether the system uses dual tone multifrequency

 

Tone

 

(DTMF) or pulse signaling on the trunk.

 

 

Tone does not appear if Signaling is set to Immediate

 

 

 

 

 

 

 

 

(T1 DID &T1 E&M trunk types only).

 

 

 

 

 

 

 

 

 

Loss package

Loop (analog

 

 

 

 

 

 

 

only)

 

 

 

 

 

 

 

 

Short CO

 

Select the appropriate loss/gain and impedance settings for

 

Medium CO

each line.

 

Long CO

 

 

 

 

 

 

 

 

Short PBX

 

 

 

 

 

 

 

Long PBX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Impedance (Ohms)

Loop (analog

 

 

 

 

 

 

 

only)

 

 

 

 

 

 

 

 

600 ohm-900 ohm

The GATM can be set to a specific impedance level.

 

 

 

 

 

 

 

 

 

 

BCM450 Troubleshooting Guide

Page 41