Nortel Networks NN43001-121 manual Signaling Server checklist

Models: NN43001-121

1 304
Download 304 pages 15.62 Kb
Page 262
Image 262

262Appendix B Configuration Examples

16Check LD 21 to confirm that PCA is activated. If not, configure LD 15 to PCA to ON to allow the incoming call to twin the PCA and make the SIP Gateway call work.

—End—

Signaling Server checklist

Use the following procedure to confirm the correct configuration of the Signaling Server.

Checking the configuration of the Signaling Server

Step Action

1Confirm that the Signaling Server is version 5.0 or higher. Refer to the Product Bulletin for any required patches for Converged Office.

2Confirm that your installation meets the memory requirements.

The maximum number of SIP CTI/TR87 users on a single Signaling Server is 5000. The Standard Signaling Server memory is 1 gigabyte (minimum requirement) and is required in the following scenarios:

a.if SIP CTI/TR87 is co-resident with PD/RL/CL application

b.if SIP CTI/TR87 is co-resident with H.323/SIP GW serving more than 200 ports, or co-resident with Terminal Proxy Server serving more than 1000 IP users

3Confirm the configuration of the Front End server and OCS Proxy server. Right-click on My Computer and choose the Computer Name tab. For more information, see Figure 102 "FQDN of the OCS 2007 Front End server" (page 263).

Nortel Communication Server 1000

Nortel Converged Office Fundamentals — Microsoft Office Communications Server 2007

NN43001-121 01.03 Standard

Release 5.0 30 April 2008