Nortel Networks NN43001-121 manual Basic Client Configuration, Port use

Models: NN43001-121

1 304
Download 304 pages 15.62 Kb
Page 58
Image 58

58 Planning and engineering

Traffic (CCS)

Traffic (Erlang)

Number of ports

 

 

 

2000

55.56

74

 

 

 

2500

69.44

90

 

 

 

3000

83.33

106

 

 

 

3500

97.22

121

 

 

 

4000

111.11

137

 

 

 

4500

125

152

 

 

 

5000

138.89

168

 

 

 

6000

166.67

198

 

 

 

7000

194.44

228

 

 

 

8000

222.22

258

 

 

 

9000

250

288

 

 

 

10 000

277.78

318

 

 

 

20 000

555.56

611

 

 

 

30 000

833.33

908

 

 

 

40 000

1111.11

1205

 

 

 

50 000

1388.89

1502

 

 

 

60 000

1666.67

1799

 

 

 

70 000

1944.44

2096

 

 

 

Basic Client Configuration

The PCAG and PCAM Class of Service (CLS) have been introduced. Basic Client Configuration (BCC) can program the new Class of Service (CLS) parameters PCAG or PCAM for PCA TNs. The CLS parameter PCAG will be the default for all PCA TNs and PCAM will be the required value for all PCAs associated with OCS 2007.

LD 11 supports the administration of telephones. BCC uses REQ commands, such as NEW, CHG, and OUT. In LD 20, BCC uses the PRT command to retrieve phones from the Call Server.

Port use

The CS 1000 uses the following ports related to TCP and TLS.

5060: TCP

5061: TLS

The dynamic port range used by Office Communicator for SIP/RTP is 1024 - 65535.

Nortel Communication Server 1000

Nortel Converged Office Fundamentals — Microsoft Office Communications Server 2007

NN43001-121 01.03 Standard

Release 5.0 30 April 2008

Copyright © 2005–2008, Nortel Networks

Page 58
Image 58
Nortel Networks NN43001-121 manual Basic Client Configuration, Port use