Page 204 of 258 Dialing Plan configuration

Configuration

To configure the main office:

Configure the ESN Control Block for CDP in LD 86.

>LD 86 REQ NEW CUST 0 FEAT ESN CDP YES MXSC 50 NCDP 4 DLTN YES

Configure the CDP Distant Steering Code (DSC) in LD 87.

>LD 87

REQ NEW

CUST 0

FEAT CDP

TYPE DSC

DSC 50

FLEN 4

RLI 12

To configure the NRS (H.323 Gatekeeper):

Create CDP Domain: “MO_BO_CDP”.

Create H.323 endpoints: “MO”, “BO”.

Create Numbering Plan entries in CDP Domain:

Add “40” for endpoint “BO”.

Add “30” for endpoint “MO”.

Add “42” for endpoint “MO”.

To configure the SRG:

Configure DN and BUID as the same number on each of the redirected IP Phones. For example, DN/BUID = 42XX.

Set the main office VoIP Trunk Access code to 3. For example, main office VoIP trunk access code = 3.

553-3001-207 Standard 2.00 January 2006

Page 204
Image 204