Nortel Networks Remote Gateway 50 LD 24 Configure Emergency Services Access. Part 2, Ddgt, Dfcl

Models: Remote Gateway 50

1 260
Download 260 pages 49.99 Kb
Page 232
Image 232

Page 232 of 258 Emergency Services configuration

LD 24 – Configure Emergency Services Access. (Part 2 of 2)

Prompt

Response

Description

 

 

 

DDGT

x...x

Directing Digits (for CAMA Trunks)(for example, 1, 11, or 911).

 

 

Up to four digits are accepted.

DFCL

x...x

Default ESA Calling Number. The input must be the following

 

 

lengths:

 

 

• On a system that is not FNP equipped, 8 or 11 digits are

 

 

accepted if the first digit of the input is ‘1’; otherwise the input

 

 

must be 7 or 10 digits.

 

 

• On a system that is FNP equipped, up to 16 digits are

 

 

allowed.

OSDN

x...x

On-Site Notification station DN. The input must be a valid single

 

 

appearance internal DN.

 

 

 

5Test ESDN using a main office telephone to confirm that main office calls exit the main office trunks.

If OSDN is used, the ESA route number must be blank to make test calls without using any trunk resources. It the route number has been configured, remove it by entering “x” at the prompt. Nortel recommends that the system administrator arrange a test call with the Public Services Access Point (PSAP).

6Configure the branch office zone on the main office.

553-3001-207 Standard 2.00 January 2006

Page 232
Image 232
Nortel Networks Remote Gateway 50 manual LD 24 Configure Emergency Services Access. Part 2, Ddgt, Dfcl, Osdn