Bandwidth Management Page 73 of 258

loss (Cpl), jitter (Cj), delay (Cd), and the R factor (Cr) — can be configured and are used to calculate the rate of bandwidth change. Increasing them from their default values causes the Sliding Maximum to decrease faster in response to the specific QoS alarm.

The QoS Coefficient (CQoS) can be varied from its default value. Increasing this value causes the Sliding Maximum to change more rapidly in response to QoS alarms. However, making this value too large will result in loss of overall bandwidth, as shown in Figure 12 below and Figure 13 on page 74.

Figure 12

Effect of the default CQos Coefficient

Main Office Configuration for Survivable Remote Gateway 50 Configuration Guide