Page 80 of 258 Bandwidth Management

Configuration using Command Line Interface

You can also configure the Adaptive Network Bandwidth Management feature using LD 117.

LD 117 — Configure Adaptive Network Bandwidth Management. (Part 1 of 6)

Command

Description

CHG CACVT <Zone> <Interval>

Configure the zone-to-zone record validity time interval, where:

Zone = 1-255

Interval = 1-(48)-255

CHG CD <Zone> <Cd>

Change the Cd coefficient in the formula that determines how quickly an alarm reduces the Sliding Maximum bandwidth for the identified zone, where:

Zone = 1-255

Cd = Cd coefficient = 1-(50)-100

CHG CPL <Zone> <Cpl>

Change the Cpl coefficient in the formula that determines how quickly an alarm reduces the Sliding Maximum bandwidth for the identified zone, where:

Zone = 1-255

Cpl = Cpl coefficient = 1-(50)-100

CHG CJ <Zone> <Jitter>

Change the Cj coefficient in the formula that determines how quickly an alarm reduces the Sliding Maximum bandwidth for the identified zone, where:

Zone = 1-255

Jitter = Jitter coefficient = 1-(50)-100