MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

Front View

q

OPERATE

OPERATE

w e r

LINK RCV XMT

Network Interface Unit WJ-NT104

t

RESET

RS232C

MODE

LINK RCV XMT

Network Interface Unit WJ-NT104

y u i

Rear View

o !0 !1 !2

IN

4

3

2

1

OUT

4

3

2

1

 

 

VIDEO

 

 

!3

XMT RCV SET UP

 

 

ALARM

G B A G B A

RS485

G 8 7 6 5 G 4 3 2 1

DC 12V

 

 

 

 

IN

RS-232C

 

10BASE-T

!4 !5 !6!7

q Operate indicator [OPERATE]

t Front panel

Is on while the power of the WJ-NT104 is turned on.

 

 

y Reset button [RESET]

w Link indicator [LINK]

Used to set or change a mode, or to restart.

Lights when the unit is connected to a normally operat-

 

ing network.

u RS-232C port [RS232]

 

Used as an alternative to the RS-232C port !4on the

e Receiving indicator [RCV]

rear panel.

Lights when data is received from the network.

 

r Transmitting indicator [XMT]

 

Lights when data is transmitted to the network.

 

6

Page 6
Image 6
Panasonic WJ-NT104 operating instructions Front View, Rear View