55
Confirmation of the set values
Turn OFF all Mode Setup switches inside the WJ-
NT104 front panel, and then press the RESET button to
restart the unit. Restarting makes the addresses
entered take effect.
Perform a communication check by means of ping
commands as follows.
qConnect the WJ-NT104 to the PC (see page 10).
PC
10Base-T
crossover cable
WJ-NT104
wClick the [START] button on the PC, and then point to [Programs]. In the program menu, choose [MS-DOS Prompt], and
enter the following commands.
Pinging 192.168.0.10 With 32 bytes of data :
Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255
Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255
Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255
Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255
Pinging 192.168.0.10 With 32 bytes of data :
Request timed out.
Request timed out.
Request timed out
Request timed out.
Pinging 192.168.0.10 With 32 bytes of data :
Destination host unreachable.
Destination host unreachable.
Destination host unreachable.
Destination host unreachable.
C: \Windows>ping 192.168.0.10 (if the WJ-NT104 address is 192.168.0.10)
The address has been set properly if the WJ-NT104 responds as follows:
If the request times out without a response from the WJ-NT104, the address may not have been set properly. Attempt to
set it again.
If the WJ-NT104 responds as below, the network setup of the PC may be wrong. Correct the setup (e.g., change the IP
address to 192.168.0.2 and the sub netmask to 255.255.255.0), and enter the ping command again.