Confirmation of the set values

Turn OFF all Mode Setup switches inside the WJ- NT104 front panel, and then press the RESET button to restart the unit. Restarting makes the addresses entered take effect.

Perform a communication check by means of ping commands as follows.

10Base-T

crossover cable

q Connect the WJ-NT104 to the PC (see page 10).

WJ-NT104

PC

wClick the [START] button on the PC, and then point to [Programs]. In the program menu, choose [MS-DOS Prompt], and enter the following commands.

C:\Windows>ping 192.168.0.10 (if the WJ-NT104 address is 192.168.0.10)

• The address has been set properly if the WJ-NT104 responds as follows:

Pinging 192.168.0.10 With 32 bytes of data :

Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255

Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255

Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255

Reply from 192.168.0.10 : bytes = 32 time = 1ms TTL = 255

If the request times out without a response from the WJ-NT104, the address may not have been set properly. Attempt to set it again.

Pinging 192.168.0.10 With 32 bytes of data :

Request timed out.

Request timed out.

Request timed out

Request timed out.

If the WJ-NT104 responds as below, the network setup of the PC may be wrong. Correct the setup (e.g., change the IP address to 192.168.0.2 and the sub netmask to 255.255.255.0), and enter the ping command again.

Pinging 192.168.0.10 With 32 bytes of data :

Destination host unreachable.

Destination host unreachable.

Destination host unreachable.

Destination host unreachable.