Remote Branch

The Top-Level menu of the remote 3800Plus modem is similar to the local 3800Plus modem with the following exceptions:

Change Directory is the only function available under the Call Setup branch.

Self and Local Analog Loop do not appear under the Test branch when using the secondary channel. When using the primary channel, the Test branch does not appear.

In the Control branch, Make Busy is not available.

The Security Branch is not available.

Exit Remote replaces Remote on the local modem's LCD.

To return to local modem operation, select ExitRem. Any changes made to configuration options while using the Remote branch are not saved until you exit the Remote branch.

The following conditions can cause Remote branch access to fail:

The local modem is not able to communicate with the remote modem because of a poor dial network or leased-line connection, or the remote modem is not a COMSPHERE (3800, 3900, or 3800Plus series) modem. If this is the case, the status message No Response appears on the LCD.

If a connection is established but the remote modem's Access from Remote configuration option is disabled, then the status message Access Disabled appears on the LCD.

If a connection is established but the wrong password is stored, the status message Password Invalid appears on the LCD. This configuration option must be enabled by the remote user. (See Remote Access Password configuration option in Chapter 8, Configure Branch.)

3980-A2-GB30-20

November 1996

10-3