Configure Branch

Dial Line

The Dial Line configuration options are used to configure the modem for operation over dial lines.

Table 8-4 shows each Dial Line configuration option as it appears on the LCD, with the Async Dial factory default setting (the default value if the modem is just being installed) shown following the colon (:) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option, a description of the available selections, and any equivalent AT commands.

Table 8-4

(1 of 4)

Dial Line Configuration Options

Modulation: V34

Nxt V34 V32bis/terbo V21/V22/BELL

Modulation determines the modem's primary dial modulation group: V.34; V.32bis and V.32terbo; or V.21, V.22bis, V.22, Bell 212A, and Bell 103J.

The factory default is V34 (V.34 modulations).

Dial LineRate: 28800(V34)

 

 

 

 

 

 

 

 

 

 

Nxt

28800(V34)

33600

31200 26400(V34) 24000(V34)

 

 

 

 

 

 

21600(V34)

19200(V34)

16800(V34)

14400(V34)

12000(V34)

9600(V34)

7200(V34)

4800(V34)

2400(V34)

- OR -

 

 

 

 

 

 

 

 

 

 

 

 

 

Nxt

19200(V32t)

16800(V32t)

14400(V32b)

12000(V32b) 9600(V32b)

7200(V32b)

4800(V32b)

 

- OR -

 

 

 

 

 

 

 

 

 

 

 

 

 

Nxt

2400(V22bis) 1200(V22)

1200(212A) 0±300(V21) 0±300(103J)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dial Line Rate. This configuration option determines the modem's data rate and modulation scheme for operation on dial lines. Online changes do not take effect until a disconnect occurs. Dial Line Rate sets the upper limit rate and modulation; lower speed connections may still be possible.

What Dial Line Rate configuration options are displayed depends the setting of Modulation.

28800(V34), 33600, 31200, 26400(V34), 24000(V34), 21600(V34), 19200(V34), 16800(V34), 14400(V34), 12000(V34), 9600(V34), 7200(V34), 4800(V34) ± The modem operates using V.34 modulation at the data rate selected. The modem can be forced by the remote modem to a lower data rate. Note that if Automode is enabled and Dial Line Rate is set to V.34, the modem can connect in a non-V.34 modulation. However, if Dial Line Rate is not set to V.34, it cannot be Automoded to V.34. The 33,600 and 31,200 bps rates are Paradyne extensions of the CCITT V.34 recommendation.

19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b) ± The modem operates using V.32terbo, V.32bis, or V.32 modulation at the data rate selected. The modem can be forced by the remote modem to a lower data rate.

2400(V22bis), 1200(V22), 1200(212A) ± Modem operates using the modulation and data rate selected.

0±300(V21), 0±300(103J) ± Modem operates in full-duplex, Asynchronous mode. These data rates do not support V.42 or MNPr error control.

The factory default is 28800(V34).

AT command equivalent is S-register S41=n.

3980-A2-GB30-20

November 1996

8-23

Page 78
Image 78
Paradyne 3800PLUS manual Dial Line Configuration Options, Modulation Nxt V34 V32bis/terbo V21/V22/BELL

3800PLUS specifications

The Paradyne 3800PLUS is a sophisticated networking device designed for various applications in high-demand environments, such as telecommunications and enterprise networks. This versatile solution is well-regarded for its robust performance, providing reliable and efficient connectivity for businesses and service providers.

One of the standout features of the Paradyne 3800PLUS is its ability to deliver high-speed data transmission. Supporting multiple protocols, it ensures seamless connectivity for data, voice, and video over the same infrastructure, reducing the need for multiple devices and simplifying network management. The device is capable of supporting both synchronous and asynchronous data formats, making it suitable for diverse networking needs.

With its advanced multiple service options, the Paradyne 3800PLUS supports various connection types, including T1, E1, and DSL, allowing it to adapt to different local area network (LAN) settings. This flexibility makes it a preferred choice for organizations that require support for both legacy systems and modern technologies. Furthermore, the device offers built-in support for various network management protocols, such as SNMP, simplifying monitoring and configuration.

Security is a significant concern in today's networking landscape, and the Paradyne 3800PLUS addresses this with integrated security features that help ensure data integrity and privacy. The device supports encryption and authentication techniques, which protect against unauthorized access and safeguard sensitive information transmitted over the network.

The Paradyne 3800PLUS is also designed with ease of use in mind. Its web-based interface simplifies configuration and management, making it accessible for network administrators regardless of their technical expertise. Additionally, the device is equipped with diagnostic tools and indicators that facilitate troubleshooting, enabling quicker resolution of connectivity issues.

In terms of scalability, the Paradyne 3800PLUS can accommodate the growing needs of businesses and service providers. Its modular design allows for easy upgrades and the addition of new features, ensuring that the network infrastructure can evolve with changing demands.

In summary, the Paradyne 3800PLUS stands out as an advanced networking solution known for its high-speed capabilities, support for various protocols, integrated security measures, user-friendly management interface, and scalability. These characteristics make it an ideal choice for organizations seeking a reliable and efficient networking solution to enhance their operations and support future growth.