Paradyne 3800PLUS manual 6 of 3800Plus AT Commands, Description, Front Panel Branch, Option

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 131
Image 131
(6 of 11)

COMSPHERE 3800Plus Modems

Table 13-1

(6 of 11)

3800Plus AT Commands

AT Command

 

 

Description

 

 

Front Panel Branch

 

 

 

 

 

&Fn

Select Factory Default Configuration Options

Configure\Factory

 

Loads factory configuration options into Active (Operating) area.

 

 

&F0

Async Dial

 

 

 

 

&F1

Sync Dial

 

 

 

 

&F2

Sync Leased: Answer

 

 

 

 

&F3

UNIX Dial

 

 

 

 

&F4

Sync Leased: Originate

 

 

 

 

&F5

Cellular (Mobile)

 

 

 

 

&F6

Cellular (PSTN)

 

 

 

 

If your modem is attached to a cellular telephone, use the &F5 command

 

 

to configure the modem for cellular communications. &F5

 

 

(Cellular(Mobile)) sets the following configuration options:

 

 

 

 

 

AT

 

 

 

 

Option

Command Value

 

 

 

 

Maximum Frame Size

\A4

 

 

 

 

 

Error Control Mode

\N4

 

 

 

 

Auto-Answer Rings

S0=3

 

 

 

 

No Answer Timeout

S7=120

 

 

 

 

No Carrier Disconnect

S10=100

 

 

 

 

V.32bis Train

S43=1

 

 

 

 

V.32bis Autorate

S76=3

 

 

 

 

V.42 ARQ Window Size

S89=9

 

 

 

 

Cellular Enhancements

S91=1

 

 

If your modem is attached to a normal dial telephone line but sometimes

 

 

communicates with a modem that is attached to a cellular phone, use the

 

 

&F6 command. &F6 (Cellular(PSTN)) sets the following configuration

 

 

options:

 

 

 

 

 

 

 

AT

 

 

 

 

Option

Command Value

 

 

 

 

Transmit Level

&I99

 

 

 

 

 

Error Control Mode

\N4

 

 

 

 

No Answer Timeout

S7=120

 

 

 

 

No Carrier Disconnect

S10=100

 

 

 

 

V.32bis Train

S43=1

 

 

 

 

V.42 ARQ Window Size

S89=9

 

 

 

 

Cellular Enhancements

S91=1

 

 

The &F0, &F3, &F5, and &F6 commands leave the modem in

 

 

AT Command mode. The other commands place the modem into

 

 

Dumb mode. The only way to return to AT command control is via

 

 

the front panel.

 

 

 

 

 

 

 

 

&Gn

V.22bis Guard Tone

 

 

Configure\Edit\Dial Line

 

&G0

Disable.

 

 

 

 

&G1

550 Hz.

 

 

 

 

&G2

1800 Hz.

 

 

 

 

 

 

 

 

 

 

13-8

November 1996

3980-A2-GB30-20

Page 131
Image 131
Paradyne 3800PLUS 6 of 3800Plus AT Commands, Description, Front Panel Branch, Select Factory Default Configuration Options