Paradyne 3800PLUS manual 4 of 3800Plus S-Registers, AT Command, Description, Front Panel Branch

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 140
Image 140
(4 of 13)

AT Command Set and S-Registers

Table 13-2

(4 of 13)

3800Plus S-Registers

AT Command

Description

Front Panel Branch

S37

Auto Redial

Auto Redial allows repeated automatic dial backup attempts by specifying the range of Directory Locations that can be tried. A redial attempt is made in response to a bad phone number, a busy signal, no answer, or no quiet answer. The modem must be in Originate mode.

On leased lines with dial backup, Auto Redial works in conjunction with the Bad Lines Auto Originate and Rate Auto Originate options.

When DTE Dialer Type is DTR=Dirs, Auto Redial works in conjunction with the DTR Cont Repeat (S38) configuration option.

Register has the following values:

0= Directory Location 1

1= Directory Locations 1±2

2= Directory Locations 1±3

3= Directory Locations 1±4

S S

S S

9= Directory Locations 1±10

NOTE: The modem must be in Originate mode to perform an automatic dial backup.

Configure\Edit\

Leased Line (Auto

Redial)

or

Configure\Edit\

Line_Dialer (DTR Auto

Redial)

S38

DTR Cont Repeat

Configure\Edit\

 

Determines whether automatic dialing of dial backup directory locations

DTE_Dialer

 

 

 

will be repeated continuously, or halted after the first pass.

 

 

Regardless of the setting of S38, dialing is locked out after ten failed

 

 

attempts to connect to the same number.

 

 

Register has the following values:

 

 

0=Disable

 

 

1=Enable

 

 

Factory setting is Disable.

 

 

 

 

S39

Receive Buffer Disconnect Delay

Configure\Edit\

 

Determines the maximum amount of time the modem can continue to send

V42/MNP/Buffer

 

data in its Receive Buffer to the DTE after the modem is commanded by

 

 

the DTE to disconnect, or after the modem detects a line disconnect.

 

 

Register has the following values:

 

 

0=Disable (Immediate disconnect)

 

 

1=1 second

 

 

2=2 seconds

 

 

S

S

 

 

S

S

 

 

255=255 seconds

 

 

Factory setting is Disable (0).

 

 

 

 

S40

Auto Make Busy

Configure\Edit\

 

Register determines if the modem goes off-hook under certain conditions.

Line Dialer

 

This register should only be enabled when the modem is located behind a

 

 

user's Private Branch Exchange (PBX).

 

 

Register has the following values:

 

 

0=Disable

 

 

1=Enable

 

 

 

Factory setting is Disable.

 

 

 

 

 

3980-A2-GB30-20

November 1996

13-17

Page 140
Image 140
Paradyne 3800PLUS 4 of 3800Plus S-Registers, AT Command, Description, Front Panel Branch, Auto Redial, DTR Cont Repeat