AT Command Set and S-Registers

Table 13-1

(11 of 11)

3800Plus AT Commands

AT Command

 

 

Description

Front Panel Branch

 

 

 

\Qn

Flow Control of DTE, Flow Control of Modem

Configure\Edit\

 

 

 

 

 

V42/MNP/Buffer

 

 

 

Flow

Flow

 

 

 

 

Control

Control of

 

 

 

 

of DTE

Modem

 

 

 

\Q0

Disable

Disable

 

 

 

\Q1

XON/XOFF

XON/XOFF

 

 

 

\Q2

CTS to DTE

Disable

 

 

 

\Q3

CTS to DTE

RTS to Mdm

 

 

 

\Q4

XON/XOFF

Disable

 

 

 

\Q5

Disable

XON/XOFF

 

 

 

\Q6

Disable

RTS to Mdm

 

 

 

 

 

\Tn

No Data Disconnect Timer

 

Configure\Edit\

 

\T0

Disable.

 

 

Line Dialer

 

 

 

 

 

\Tn Where n is a value from 1 to 255 in 1-minute increments.

 

 

 

 

 

\Xn

XON/XOFF Passthrough Flow Control

 

Configure\Edit\

 

\X0

Disable.

 

 

V42/MNP/Buffer

 

 

 

 

 

\X1

Enable.

 

 

 

 

 

 

 

%An

Error Control Fallback Character

 

Configure\Edit\

 

%An Where n is an ASCII value from 0 to 127. Factory default is

V42/MNP/Buffer

 

 

 

 

013 ASCII.

 

 

 

 

 

 

 

%Cn

MNP5 Data Compression

 

Configure\Edit\

 

%C0

Disable.

 

 

V42/MNP/Buffer

 

 

 

 

 

%C1

Enable.

 

 

 

 

 

 

 

 

IHn

V.42bis Compression

 

 

Configure\Edit\

 

IH0

Disable.

 

 

V42/MNP/Buffer

 

 

 

 

 

IH1 Transmit only. (Not available from DCP.)

 

 

IH2 Receive only. (Not available from DCP.)

 

 

IH3 Transmit and Receive. (Equivalent to Enabled option on DCP.)

 

 

 

 

 

+FCLASS=n

Service Class Selection

 

 

 

Normally set by fax software, Service Class Selection determines the fax

 

 

protocol. The command is sent to the modem in the format +FCLASS=n,

 

 

where n can be set to one of three values:

 

 

 

0=Data

 

 

 

 

1=Class 1 Fax (EIA 578)

 

 

 

2=Class 2 Fax (EIA/TIA SP-2388 dated 20 August 1990)

 

 

In the format +FCLASS?, the +FCLASS command returns the current

 

 

Service Class: 0, 1, or 2. In the format +FCLASS=?, the +FCLASS

 

 

command returns the Service Classes available: 0, 1, 2.

 

 

NOTE: Other fax commands supported by the 3800Plus modems are not

 

 

 

documented in this manual because they are not normally issued

 

 

 

by the user. They follow the EIA 578 and EIA/TIA SP-2388

 

 

 

specifications.

 

 

 

 

 

 

 

 

 

3980-A2-GB30-20

November 1996

13-13

Page 136
Image 136
Paradyne 3800PLUS Flow Control of DTE, Flow Control of Modem, Q2, No Data Disconnect Timer, T0, X0, MNP5 Data Compression

3800PLUS specifications

The Paradyne 3800PLUS is a sophisticated networking device designed for various applications in high-demand environments, such as telecommunications and enterprise networks. This versatile solution is well-regarded for its robust performance, providing reliable and efficient connectivity for businesses and service providers.

One of the standout features of the Paradyne 3800PLUS is its ability to deliver high-speed data transmission. Supporting multiple protocols, it ensures seamless connectivity for data, voice, and video over the same infrastructure, reducing the need for multiple devices and simplifying network management. The device is capable of supporting both synchronous and asynchronous data formats, making it suitable for diverse networking needs.

With its advanced multiple service options, the Paradyne 3800PLUS supports various connection types, including T1, E1, and DSL, allowing it to adapt to different local area network (LAN) settings. This flexibility makes it a preferred choice for organizations that require support for both legacy systems and modern technologies. Furthermore, the device offers built-in support for various network management protocols, such as SNMP, simplifying monitoring and configuration.

Security is a significant concern in today's networking landscape, and the Paradyne 3800PLUS addresses this with integrated security features that help ensure data integrity and privacy. The device supports encryption and authentication techniques, which protect against unauthorized access and safeguard sensitive information transmitted over the network.

The Paradyne 3800PLUS is also designed with ease of use in mind. Its web-based interface simplifies configuration and management, making it accessible for network administrators regardless of their technical expertise. Additionally, the device is equipped with diagnostic tools and indicators that facilitate troubleshooting, enabling quicker resolution of connectivity issues.

In terms of scalability, the Paradyne 3800PLUS can accommodate the growing needs of businesses and service providers. Its modular design allows for easy upgrades and the addition of new features, ensuring that the network infrastructure can evolve with changing demands.

In summary, the Paradyne 3800PLUS stands out as an advanced networking solution known for its high-speed capabilities, support for various protocols, integrated security measures, user-friendly management interface, and scalability. These characteristics make it an ideal choice for organizations seeking a reliable and efficient networking solution to enhance their operations and support future growth.