Configure Branch

Table 8-1

(7 of 7)

DTE Interface Configuration Options

TX Clock Source: Internal

Nxt Internal External RXC_Loop

Transmit Clock Source. Determines the source of timing for synchronous data transmitted from the DTE.

Internal ± The transmit data's clock source is derived from the modem's internal clock and output on Pin 15 (TXC) of the RS-232D interface.

External ± The transmit data's clock source is provided by the DTE on Pin 24 (EXT) on the RS-232D interface. This configuration option automatically disables Autorate, Automode, and Asymmetric Rate mode when running V.34 modulation.

RXC Loop ± The modem's transmit clock is derived from its received signal and is output on Pin 15 (TXC) of the RS-232D interface.

NOTE: This configuration option only appears if Async/Sync Mode is configured for Sync.

The factory default is Internal.

AT command equivalent is &Xn.

CT111_Rate Cntl: Disable

Nxt Disable Fallback1 Fallback2

CT111 Rate Control. Allows the DTE to control modem rate via Pin 23 of the RS-232D interface. This configuration option determines the effect of the DTE Rate control signal. CT111 is also known as CH on the RS-232D interface.

Disable ± Disregards CT111 Rate Control.

Fallback1 ± Forces the modem to decrease its configured data rate to the next lower data rate when CT111 is Off. Valid only for V.32bis, V.33, V.29 modulation. Modem will only fall back within the same modulation scheme. When CT111 turns ON, the modem returns to its previous data rate.

Fallback2 ± Forces the modem to decrease two data rates while remaining in the same modulation scheme. When CT111 turns ON, the modem returns to its previous data rate.

NOTE: This configuration option is only valid in Async Direct mode and Synchronous mode. For proper operation, disable the Autorate and Automode configuration options. CT111 Rate Control is not supported with V.34.

The factory default is Disable.

AT command equivalent is S-register S61=n.

DTE Rate=VF: Disable

End Disable Enable

DTE Rate = VF Rate. Forces the data rate of the connection between the DTE (computer) and the modem to be the same as the VF (telephone line) rate.

Disable ± The DTE rate is the value of the Async DTE Rate configuration option.

Enable ± The DTE rate is identical with the VF rate.

The factory default is Disable.

AT command equivalent is S-register S90=n.

3980-A2-GB30-20

November 1996

8-13

Page 68
Image 68
Paradyne 3800PLUS manual TX Clock Source Internal Nxt Internal External RXCLoop, DTE Rate=VF Disable End Disable Enable

3800PLUS specifications

The Paradyne 3800PLUS is a sophisticated networking device designed for various applications in high-demand environments, such as telecommunications and enterprise networks. This versatile solution is well-regarded for its robust performance, providing reliable and efficient connectivity for businesses and service providers.

One of the standout features of the Paradyne 3800PLUS is its ability to deliver high-speed data transmission. Supporting multiple protocols, it ensures seamless connectivity for data, voice, and video over the same infrastructure, reducing the need for multiple devices and simplifying network management. The device is capable of supporting both synchronous and asynchronous data formats, making it suitable for diverse networking needs.

With its advanced multiple service options, the Paradyne 3800PLUS supports various connection types, including T1, E1, and DSL, allowing it to adapt to different local area network (LAN) settings. This flexibility makes it a preferred choice for organizations that require support for both legacy systems and modern technologies. Furthermore, the device offers built-in support for various network management protocols, such as SNMP, simplifying monitoring and configuration.

Security is a significant concern in today's networking landscape, and the Paradyne 3800PLUS addresses this with integrated security features that help ensure data integrity and privacy. The device supports encryption and authentication techniques, which protect against unauthorized access and safeguard sensitive information transmitted over the network.

The Paradyne 3800PLUS is also designed with ease of use in mind. Its web-based interface simplifies configuration and management, making it accessible for network administrators regardless of their technical expertise. Additionally, the device is equipped with diagnostic tools and indicators that facilitate troubleshooting, enabling quicker resolution of connectivity issues.

In terms of scalability, the Paradyne 3800PLUS can accommodate the growing needs of businesses and service providers. Its modular design allows for easy upgrades and the addition of new features, ensuring that the network infrastructure can evolve with changing demands.

In summary, the Paradyne 3800PLUS stands out as an advanced networking solution known for its high-speed capabilities, support for various protocols, integrated security measures, user-friendly management interface, and scalability. These characteristics make it an ideal choice for organizations seeking a reliable and efficient networking solution to enhance their operations and support future growth.