Paradyne 3800PLUS manual Loc Analog Loop, 1. Local Analog Loopback, AT Command Equivalent

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 51
Image 51
Loc Analog Loop

Test Branch

Loc Analog Loop

Loc Analog Loop performs a local analog loopback (CCITT V.54 Loop 3), Figure 7-1, that verifies modem operation as well as the connection between the DTE and modem. The modem must be offline and in synchronous or asynchronous Direct mode to perform this test, otherwise Invalid Command appears.

To access Loc Analog Loop from the Test branch, make the following selections:

Test :

Loc_Analog_Loop

F1 F2 F3

Press the Figure 7-1. Local Analog Loopback key until Loc Analog Loop appears. Press any function key to start this test.

Test : Local Loop

Started

F1 F2 F3

The message Started appears on the LCD, and the Test LED lights for the duration of the test.

If the Test Timeout configuration option is enabled,

Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Tests section in Chapter 7, Configure Branch.

A Ring Indicate during this test can cause errors.

To exit this function and remain in the Test branch,

press the Manual background key. To exit and return to the Top-Level

menu, press the Manual background key.

AT Command Equivalent

The AT command for Local Analog Loopback is &T1.

Figure 7-1. Local Analog Loopback

3980-A2-GB30-20

November 1996

7-3

Page 51
Image 51
Paradyne 3800PLUS manual Loc Analog Loop, 1. Local Analog Loopback, AT Command Equivalent