Paradyne 3800PLUS manual 8 of 3800Plus S-Registers, AT Command, Description, Front Panel Branch

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 144
Image 144
(8 of 13)

AT Command Set and S-Registers

Table 13-2

(8 of 13)

3800Plus S-Registers

AT Command

Description

Front Panel Branch

S53

V.54 Address

Identifies the address of the modem to be placed in a loopback test.

Register has the following values:

0 =Disable

1±34 =Modem address

Factory setting is Disable.

Configure\Edit\Tests

S54

V.54 Device Type

Configure\Edit\Tests

 

Identifies where the modem is physically located in the network.

 

 

Register has the following values:

 

 

0=Peripheral

 

 

1=Intermediate

 

 

Factory setting is Peripheral.

 

 

 

 

S55

Access from Remote

Configure\Edit\Misc

 

Register determines if a modem's DCP can be accessed by a remote

 

 

modem.

 

 

Register has the following values:

 

 

0=Enable

 

 

1=Disable

 

 

The factory default templates do not affect S55.

 

 

 

 

S56

Remote Access Password (Part 1)

Configure\Edit\Misc

 

Register allows entry of the first pair (leftmost) of digits of a remote access

 

 

password. Any value from 00 to 99 is valid. For example, if the remote

 

 

access password is 12345678, then S56=12.

 

 

 

 

S57

Remote Access Password (Part 2)

Configure\Edit\Misc

 

Register allows entry of the second pair of digits of a remote access

 

 

password. Any value from 00 to 99 is valid.

 

 

 

 

S58

Remote Access Password (Part 3)

Configure\Edit\Misc

 

Register allows entry of the third pair of digits of a remote access

 

 

password. Any value from 00 to 99 is valid.

 

 

 

 

S59

Remote Access Password (Part 4)

Configure\Edit\Misc

 

Register allows entry of the fourth pair (rightmost) of digits of a remote

 

 

access password. Any value from 00 to 99 is valid.

 

 

 

 

S61

CT111 Rate Control

Configure\Edit\

 

Register determines if CT111 Rate is disabled, set for Fallback 1 or

DTE Interface

 

Fallback 2. CT111 Rate allows the DTE to control modem rate via Pin 23

 

 

of the EIA-232-D interface. This configuration option determines the effect

 

 

of the DTE Rate Control signal. It is only valid in Async Direct mode and

 

 

Synchronous mode. For proper operation, disable the V32bis Autorate and

 

 

V32bis Automode configuration options.

 

 

Register has the following values:

 

 

0=Disable

 

 

1=Fallback 1

 

 

2=Fallback 2

 

 

Factory setting is Disable.

 

 

 

 

3980-A2-GB30-20

November 1996

13-21

Page 144
Image 144
Paradyne 3800PLUS 8 of 3800Plus S-Registers, AT Command, Description, Front Panel Branch, V.54 Address, V.54 Device Type