Configure Branch

Table 8-6

(3 of 6)

V.42/MNP/Buffer Configuration Options

*EC Fallbck Char: 013 ASCI

Nxt " 013 ASCI

Error Control Fallback Character. This configuration option allows you to enter the ASCII value of the error control fallback character. This provides the remote modem with the ability to end the error control link negotiating (handshaking) sequence by sending this character. The modems will connect in Buffer mode (no error control). Online changes do not take effect until a disconnect occurs.

When the modem receives this fallback character it switches to Buffer mode and transmits an EC fallback character to the DTE. When comparing incoming characters for a match against the EC fallback character, the modem ignores parity.

The factory default is 13 ASCII.

NOTE: This configuration option is only available if EC Negotiate Buffer is configured for Disab&Switch.

AT command equivalent is %An.

*Flw Cntl of DTE: CTS_to_DTE

Nxt CTS_to_DTE Disable XON/XOFF

Flow Control of DTE. Determines how the modem controls the flow of data from the DTE.

CTS to DTE ± Method of flow control in which the modem raises and lowers its CTS interface lead to indicate when the DTE should start and stop sending data.

Disable ± The modem cannot control the flow of data from the DTE.

XON/XOFF ± Method of flow control in which the modem sends XON and XOFF characters to the DTE to start and stop the flow of data.

The factory default is CTS to DTE.

AT command equivalent is \Qn.

*Flw Cntl of Mdm: Disable

Nxt Disable XON/XOFF RTS_to_Mdm

Flow Control of Modem. Determines how the DTE controls the flow of data from the modem.

Disable ± The DTE cannot control the flow of data from the modem.

XON/XOFF ± Method of flow control in which the modem starts and stops data flow based upon XON and XOFF characters received from the DTE.

RTS to Modem ± Method of flow control in which the modem respectively starts and stops data transmission based upon the ON and Off state of the DTE's RTS signal.

The factory default is Disable.

AT command equivalent is \Qn.

*This configuration option is only available if Async/Sync Mode is configured for Async. Refer to the DTE Interface configuration options group for more on Async/Sync Mode.

3980-A2-GB30-20

November 1996

8-33

Page 88
Image 88
Paradyne 3800PLUS manual EC Fallbck Char 013 Asci Nxt 013 Asci, Flw Cntl of DTE CTStoDTE Nxt CTStoDTE Disable XON/XOFF

3800PLUS specifications

The Paradyne 3800PLUS is a sophisticated networking device designed for various applications in high-demand environments, such as telecommunications and enterprise networks. This versatile solution is well-regarded for its robust performance, providing reliable and efficient connectivity for businesses and service providers.

One of the standout features of the Paradyne 3800PLUS is its ability to deliver high-speed data transmission. Supporting multiple protocols, it ensures seamless connectivity for data, voice, and video over the same infrastructure, reducing the need for multiple devices and simplifying network management. The device is capable of supporting both synchronous and asynchronous data formats, making it suitable for diverse networking needs.

With its advanced multiple service options, the Paradyne 3800PLUS supports various connection types, including T1, E1, and DSL, allowing it to adapt to different local area network (LAN) settings. This flexibility makes it a preferred choice for organizations that require support for both legacy systems and modern technologies. Furthermore, the device offers built-in support for various network management protocols, such as SNMP, simplifying monitoring and configuration.

Security is a significant concern in today's networking landscape, and the Paradyne 3800PLUS addresses this with integrated security features that help ensure data integrity and privacy. The device supports encryption and authentication techniques, which protect against unauthorized access and safeguard sensitive information transmitted over the network.

The Paradyne 3800PLUS is also designed with ease of use in mind. Its web-based interface simplifies configuration and management, making it accessible for network administrators regardless of their technical expertise. Additionally, the device is equipped with diagnostic tools and indicators that facilitate troubleshooting, enabling quicker resolution of connectivity issues.

In terms of scalability, the Paradyne 3800PLUS can accommodate the growing needs of businesses and service providers. Its modular design allows for easy upgrades and the addition of new features, ensuring that the network infrastructure can evolve with changing demands.

In summary, the Paradyne 3800PLUS stands out as an advanced networking solution known for its high-speed capabilities, support for various protocols, integrated security measures, user-friendly management interface, and scalability. These characteristics make it an ideal choice for organizations seeking a reliable and efficient networking solution to enhance their operations and support future growth.