Paradyne 3800PLUS 2 of 3800Plus AT Commands, Description, Front Panel Branch, Dial Stored Number

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 127
Image 127
(2 of 11)

COMSPHERE 3800Plus Modems

Table 13-1

(2 of 11)

3800Plus AT Commands

AT Command

 

Description

Front Panel Branch

 

 

 

 

Dn (Cont'd)

, ±

Pause. Causes the modem to pause before processing the next

 

 

 

character in the dial string. The length of this pause is determined by

 

 

 

the setting of the Pause Time configuration option (see Line Dialer

 

 

 

configuration option group) or by value held in S-register S8.

 

 

; ± Return to Command mode. Modem returns to Command mode after

 

 

 

 

 

dialing a number without disconnecting the call. This is useful when

 

 

 

the number exceeds 40 characters, or when the wait time between

 

 

 

parts of a dial string is unknown. This modifier disables the any-key

 

 

 

abort function.

 

 

Space, ± , and ( ) . These characters are ignored by the dial string and can

 

 

 

be included in the dial string to enhance readability.

 

 

 

 

DS=n

Dial Stored Number

Call Setup\Dial\

 

Dials the number stored in Location n (1±10). (To store a telephone

Dial Directory:

 

number, refer to the &Zn=x command.)

 

 

If any character is received from the DTE before the modem goes online,

 

 

the dial sequence is aborted. This is known as any-key abort.

 

 

 

 

En

Command Character Echo

Configure\Edit\

 

E0

Disables echo to the DTE.

DTE Dialer

 

E1

Enables echo to the DTE.

 

 

 

 

Hn

Hook Switch Control

H0: Call

 

H0

Modem goes on-hook.

Setup\Disconnect

 

H1

Modem goes off-hook.

or

 

 

 

Control\Remove Make

 

 

 

Busy

 

 

 

H1: Control\ Make Busy

 

 

 

In

Identification

Status\Identity

 

I0

Displays product code; default is 144.

 

 

I1

Displays 3-digit firmware revision number.

 

 

I2

Performs an EPROM check.

 

 

I3

Displays the modem's serial number.

 

 

I4

Displays the modem's model number. The model number of a

 

 

 

3810Plus begins with 3980. The model number of a 3811Plus

 

 

 

begins with 3981. The model number of a 3820Plus begins with

 

 

 

3982.

 

 

I5

Displays the part number of the circuit card.

 

 

I6

Displays the firmware release number.

 

 

I9

Displays 3-digit firmware revision number (same as I1).

 

 

I10=n Changes the value of the product code displayed by the

 

 

 

I0 command; n is a number from 0 to 4:

 

 

 

I10=0 sets product code to 144

 

 

 

I10=1 sets product code to 240

 

 

 

I10=2 sets product code to 480

 

 

 

I10=3 sets product code to 960

 

 

 

I10=4 sets product code to 120

 

 

I11

Performs a checksum of the modem's firmware and displays the

 

 

 

results in hexadecimal. (There is no DCP equivalent of this

 

 

 

command.)

 

 

I19

Displays the entire firmware revision level.

 

 

 

 

 

13-4

November 1996

3980-A2-GB30-20

Page 127
Image 127
Paradyne 3800PLUS 2 of 3800Plus AT Commands, Description, Front Panel Branch, Dial Stored Number, Command Character Echo