3800Plus S-Registers

AT Command

Description

Front Panel Branch

 

 

 

S74

Network Position Identification

Configure\Edit\Misc

 

Register identifies each modem as either a control or tributary modem.

 

 

Register has the following values:

 

 

0=Tributary

 

 

1=Control

 

 

Factory setting is Tributary for the 3810Plus and the 3820Plus.

 

 

Factory setting is Control for the 3811Plus.

 

 

 

 

S75

Network Management Address

Configure\Edit\Dial

 

Register determines the modem's network address. This address is used

 

 

when accessing the modem from the NMS.

 

 

Enter a value from 0 (network address 001) to 255 (network address 256).

 

 

The factory default templates do not affect S75.

 

 

 

 

S76

Autorate (Dial Line)

Configure\Edit\

 

Register determines if Autorating is used on dial lines when connected in

Dial Line

 

V.32bis or V.34 mode.

 

 

Register has the following values:

 

 

0=Enable

 

 

1=Disable

 

 

2=Start at 4800 bps

 

 

3=Start at 9600 bps

 

 

Factory setting is Enable.

 

 

 

 

S77

DTR Alarm Reporting

Configure\Edit\Misc

 

Register determines whether an alarm is sent to the NMS controller when

 

 

the DTR signal has been off for more than 10 seconds.

 

 

Register has the following values:

 

 

0=Disable

 

 

1=Enable

 

 

The factory default templates do not affect S77.

 

 

 

 

S78

Automode (Dial Line)

Configure\Edit\

 

Register allows the modem (when operating on dial lines) to automatically

Dial Line

 

detect and connect to the remote modem's modulation scheme.

 

 

If the modem is in a modem pool attached to a System 85 Private Branch

 

 

Exchange (PBX), S78 should be set to 2. This modifies parameters used

 

 

during connection to the PBX.

 

 

Register has the following values:

 

 

0=Enable

 

 

1=Disable

 

 

2=System 85

 

 

Factory setting is Enable.

 

 

 

 