RTS/CTS Delay: 0 msec

Nxt 0msec 10msec 50msec 150msec 600msec

Request-to-Send/Clear-to-Send Delay. RTS/CTS Delay sets the delay time between the modem receiving RTS from the DTE and the modem sending CTS to the DTE.

This delay is only valid in Async Direct mode and synchronous applications when it is necessary to have a short delay between the time the DTE raises RTS and the time the modem presents CTS to allow the DTE to send data.

NOTE: For this configuration option to be valid, both the RTS Action and the CTS Control configuration options must be set for Stndrd RS232. If RTS Action is set for Ignore, RTS is always ON and this configuration option has no effect.

The factory default is 0 milliseconds.

AT command equivalent is S-register S26=n.

LSD Control: Stndrd_RS232

Nxt Stndrd_RS232 Forced_On WinkWhenDisc Follows_DTR Sim_Cntl_Car =DTR/DiscOff BridgeRetrain

Line Signal Detect Control. LSD is a signal indicating that the carrier signal is being received from the remote modem. It is normally turned Off to the DTE when the power level of the received carrier signal drops below the carrier detect threshold.

Standard RS232 ± LSD is ON when the modem detects the remote modem's carrier signal. LSD turns Off when the carrier signal strength drops below carrier detect threshold.

Forced On ± Forces LSD to be ON at all times.

Wink When Disconnect ± LSD is normally forced ON, but can be turned Off for 1 to 2 seconds upon a disconnect. This is used for UNIXr DTEs.

Follows DTR ± The state of LSD follows the state of DTR. When DTR turns ON, LSD turns ON. When DTR turns Off, LSD turns Off.

Simulated Control Carrier ± LSD follows the state of RTS of the remote DTE via the V.13 simulated control carrier signaling. This is required for hosts that cannot support full-duplex operation. Valid only in Synchronous mode and Asynchronous Direct mode.

NOTE: If LSD Control is set for simulated control carrier, then the RTS Action configuration option on the remote modem must be set for Simulated Control Carrier.

=DTR/Disconnect Off ± The state of LSD follows the state of DTR except when disconnecting once a connection is established. In this instance, DTR remains ON and LSD turns Off. DTR must then toggle Off and then ON again for LSD to turn ON. This setting is required for AT&T DATAKITr dial-out applications.

BridgeRetrain ± LSD behaves as if it were set for Standard RS232, except that it is turned off when a retrain condition lasts longer than 10 seconds, and turned on again when no retrain condition is detected for a period of 10 seconds.

NOTE: If LSD Control is set for =DTR/DiscOff, then the DTR Action configuration option must be set for Stndrd_RS232.

For Async Dial, Sync Dial, and Sync Leased, Stndrd_RS232 is the factory default.

For UNIX Dial, WinkWhenDisc is the factory default.

AT command equivalent is &Cn.

8-12

November 1996

3980-A2-GB30-20

Page 67
Image 67
Paradyne 3800PLUS manual RTS/CTS Delay 0 msec Nxt 0msec 10msec 50msec 150msec 600msec

3800PLUS specifications

The Paradyne 3800PLUS is a sophisticated networking device designed for various applications in high-demand environments, such as telecommunications and enterprise networks. This versatile solution is well-regarded for its robust performance, providing reliable and efficient connectivity for businesses and service providers.

One of the standout features of the Paradyne 3800PLUS is its ability to deliver high-speed data transmission. Supporting multiple protocols, it ensures seamless connectivity for data, voice, and video over the same infrastructure, reducing the need for multiple devices and simplifying network management. The device is capable of supporting both synchronous and asynchronous data formats, making it suitable for diverse networking needs.

With its advanced multiple service options, the Paradyne 3800PLUS supports various connection types, including T1, E1, and DSL, allowing it to adapt to different local area network (LAN) settings. This flexibility makes it a preferred choice for organizations that require support for both legacy systems and modern technologies. Furthermore, the device offers built-in support for various network management protocols, such as SNMP, simplifying monitoring and configuration.

Security is a significant concern in today's networking landscape, and the Paradyne 3800PLUS addresses this with integrated security features that help ensure data integrity and privacy. The device supports encryption and authentication techniques, which protect against unauthorized access and safeguard sensitive information transmitted over the network.

The Paradyne 3800PLUS is also designed with ease of use in mind. Its web-based interface simplifies configuration and management, making it accessible for network administrators regardless of their technical expertise. Additionally, the device is equipped with diagnostic tools and indicators that facilitate troubleshooting, enabling quicker resolution of connectivity issues.

In terms of scalability, the Paradyne 3800PLUS can accommodate the growing needs of businesses and service providers. Its modular design allows for easy upgrades and the addition of new features, ensuring that the network infrastructure can evolve with changing demands.

In summary, the Paradyne 3800PLUS stands out as an advanced networking solution known for its high-speed capabilities, support for various protocols, integrated security measures, user-friendly management interface, and scalability. These characteristics make it an ideal choice for organizations seeking a reliable and efficient networking solution to enhance their operations and support future growth.