Paradyne 3800PLUS manual 7 of 3800Plus S-Registers, AT Command, Description, Front Panel Branch

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 143
Image 143
(7 of 13)

COMSPHERE 3800Plus Modems

Table 13-2

(7 of 13)

3800Plus S-Registers

AT Command

Description

Front Panel Branch

S47

Auto Dial Standby

Register determines if the modem performs an automatic dial standby if in Dial Backup mode.

Register has the following values:

0=Disable 1=15 minutes 2=1 hour 3=4 hours

255=Test(2min)

Factory setting is Disable.

Configure\Edit\ Leased Line

S48

Leased-Line Carrier On Level

Configure\Edit\

 

Register determines if the modem disconnects if the carrier signal on

Leased Line

 

leased lines falls below ±26 dBm or ±43 dBm.

 

 

Register has the following values:

 

 

0= ±43 dBm

 

 

1= ±26 dBm

 

 

Factory setting is ±43 dBm.

 

 

 

 

S49

Transmit Buffer Disconnect Delay

Configure\Edit\

 

Determines the maximum amount of time the modem can continue to send

V42/MNP/Buffer

 

data in its Transmit Buffer to the remote modem after it is commanded by

 

 

the DTE to disconnect.

 

 

Register has the following values:

 

 

0=Disable (Immediate disconnect)

 

 

1=1 second

 

 

2=2 seconds

 

 

S

S

 

 

S

S

 

 

255=255 seconds

 

 

Factory setting is 10 seconds.

 

 

 

 

S51

DTE RL (CT140)

Configure\Edit\Tests

 

Register determines if the modem performs a remote digital loopback if it

 

 

receives a CT140 signal from the DTE.

 

 

Register has the following values:

 

 

0=Disable

 

 

1=Enable

 

 

 

Factory setting is Disable.

 

 

 

 

S52

DTE LL (CT141)

Configure\Edit\Tests

 

Register determines if the modem performs a local analog loopback if it

 

 

receives a CT141 signal from the DTE.

 

 

Register has the following values:

 

 

0=Disable

 

 

1=Enable

 

 

 

Factory setting is Disable.

 

 

 

 

 

13-20

November 1996

3980-A2-GB30-20

Page 143