Paradyne 3800PLUS manual of Leased Line Configuration Options, FallFwdDelay Disable, Auto Redial

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 85
Image 85
(4 of 4)

COMSPHERE 3800Plus Modems

Table 8-5

(4 of 4)

Leased Line Configuration Options

*Auto Redial

Nxt Dir_1 Dirs_1-2 Dirs_1-3 Dirs_1-4 Dirs_1-5 Dirs_1-6 Dirs_1-7 Dirs_1-8 Dirs_1-9 Dirs_1-10

Auto Redial. Works in conjunction with the Bad Lines Auto Originate and Rate Auto Originate options. It allows repeated automatic dial backup attempts by specifying the range of directory locations that can be tried. The modem must be in Originate mode.

Dir_1 ± The modem will use only directory location 1 for automatic dial backups.

Dirs_1-2± The modem will use directory location 2 in the event of call failure using directory location 1. Dirs_1-3± The modem will use directory location 3 in the event of call failure using the preceding entries.

SS

SS

Dirs_1-10± The modem will use directory location 10 in the event of call failure using the preceding entries.

AT command equivalent is S37=n.

*AutoDialStandby: Disable

Nxt Disable 15min 1hr 4hr Test(2min) Adv15min Adv30min Adv1hr AdvTest2min

Automatic Dial Standby. Permits a modem operating on dial lines (regardless of the method of dialing origination) to check the quality of the leased lines periodically and, if they are good, to disconnect from the dial lines and resume operations on the leased lines.

The time interval that the modem uses to check the quality of the leased lines is determined by the configuration option. These intervals are 15 minutes, 1 hour, and 4 hours.

The normal settings cause an interruption of data flow on the dial line while the leased-line connection is checked. The Advanced settings allow data flow to continue without interruption while the leased line is evaluated.

If Advanced settings are used, then both modems must be configured to the same Advanced setting.

The Test(2min) selections are for testing this feature only.

The factory default is Disable.

AT command equivalent is S-register S47=n.

*CarrierOn Level: ± 43dbm End ± 43dbm ±26dbm

Carrier On Level. This configuration option controls the carrier detection threshold for leased lines. When the power level of the receive carrier signal drops 2 dBm below this level (either ±26 dBm or ±43 dBm), LSD turns Off. When the carrier signal is greater than this level, LSD turns ON.

The factory default is ±43dbm.

AT command equivalent is S-register S48=n.

*FallFwdDelay: Disable

End Disable 5_mins 15_mins 1_hour

Fall Forward Delay. Provides an initial delay before leased or dial lines are monitored for fall forward conditions. After the timer expires, monitoring occurs as usual. Possible delay times are 5 minutes, 15 minutes, or 1 hour.

The factory default is Disable (no delay).

NOTE: Fall Forward Delay appears under both the Dial Line configuration options and the Leased Line configuration options, but the same setting is used for both. Changing it in one place effectively changes it in the other.

There is no analogous AT command, so this option is not available for modems without a shared or integral DCP.

* This configuration option is only available if the Sync Leased factory preset template is selected.

8-30

November 1996

3980-A2-GB30-20

Page 85
Image 85
Paradyne 3800PLUS manual of Leased Line Configuration Options, FallFwdDelay Disable, Auto Redial, AutoDialStandby Disable