3800Plus S-Registers

AT Command

Description

Front Panel Branch

S62

V.25bis Coding

Configure\Edit\

 

Register identifies to the modem the type of coding used by the DTE while

DTE Dialer

 

in V.25bis mode.

 

 

Register has the following values:

 

 

0=ASCII

 

 

1=EBCDIC

 

 

Factory setting is ASCII.

 

 

 

 

S63

V.25bis Idle Character

Configure\Edit\

 

Register identifies to the modem the type of idle fill used by the DTE while

DTE Dialer

 

in V.25bis mode.

 

 

Register has the following values:

 

 

0=Mark

 

 

1=Flag

 

 

Factory setting is Mark.

 

 

 

 

S64

V.25bis New Line Character

Configure\Edit\

 

Register identifies to the modem the type of line terminator used by the

DTE Dialer

 

DTE while in V.25bis mode.

 

 

Register has the following values:

 

 

0=Carriage Return and Line Feed

 

 

1=Carriage Return

 

 

2=Line Feed

 

 

Factory setting is carriage return and line feed (CR + LF).

 

 

 

 

S66

NMS Call Messages

Configure\Edit\Misc

 

Register determines if the modem sends information regarding status (Call

 

 

Progress) and/or sends summarized call statistics (Call Connect) to the

 

 

dial network management system (COMSPHERE 6700 Series NMS).

 

 

Register has the following values:

 

 

0=Call Connect & Progress

 

 

1=Disable

 

 

2=Call Connect Only

 

 

3=Call Progress Only

 

 

The factory default templates do not affect S66.

 

 

 

 

S67

Directory Location 1 Callback

Configure\Edit\Misc

 

Register determines if the modem uses the single number callback

 

 

function.

 

 

Register has the following values:

 

 

0=Disable

 

 

1=Enable

 

 

Factory setting is Disable.

 

 

 

 

S69

Make Busy Via DTR

Configure\Edit\

 

Register determines if the modem goes off-hook (busy) when DTR is Off.

Line Dialer

 

Register has the following values:

 

 

0=Disable

 

 

1=Enable

 

 

Factory setting is Disable.

 

 

 

 

13-22