Paradyne 3800PLUS manual 2 of 3800Plus S-Registers, AT Command, Description, Front Panel Branch

Models: 3800PLUS

1 192
Download 192 pages 59.34 Kb
Page 138
Image 138
(2 of 13)

AT Command Set and S-Registers

Table 13-2

(2 of 13)

3800Plus S-Registers

AT Command

Description

Front Panel Branch

S4

Line Feed Character

Configure\Edit\

 

Register determines ASCII value used as the line feed character.

DTE Dialer

 

Enter a value from 0±127 for the line feed character.

 

 

Factory setting is 10 (ASCII carriage return or line feed).

 

 

 

 

S5

Backspace Character

Configure\Edit\

 

Register determines ASCII value used as the backspace (Backspace key).

DTE Dialer

 

This character moves the cursor to the left and erases the previous

 

 

character.

 

 

Enter a value from 0±127.

 

 

Factory setting is 08 (backspace key).

 

 

 

 

S6

Blind Dial Pause

Configure\Edit\

 

Register determines how long (in seconds) the modem waits after going

Line Dialer

 

off-hook before dialing a telephone number if using result code X0, X1, or

 

 

X3.

 

 

Enter a value from 2±255 seconds.

 

 

Factory setting is 2 seconds.

 

 

 

 

S7

No Answer Timeout

Configure\Edit\

 

Register determines how long (in seconds) an originating modem waits

Line Dialer

 

before abandoning a call when no answer tone is received.

 

 

Enter a value from 1±255 seconds.

 

 

Factory setting is 45 seconds.

 

 

 

 

S8

``,º Pause Time for the Dial Modifier

Configure\Edit\

 

Register determines how long (in seconds) the modem pauses when it

Line Dialer

 

encounters a comma (,) in the Dial command string.

 

 

Enter a value from 0±255 seconds.

 

 

Factory setting is 2 seconds.

 

 

 

 

S10

No Carrier Disconnect

Configure\Edit\

 

Register determines how long (in tenths of seconds) the modem allows the

Line Dialer

 

carrier signal to be off before disconnecting the call.

 

 

Enter a value from 0±254 in 0.1 second increments. (A value of 255

 

 

disables this register.)

 

 

Factory setting is 20 (2 seconds).

 

 

 

 

S12

Escape Guard Time

Configure\Edit\

 

Register sets the value (in 20-millisecond increments) for the required

DTE Dialer

 

pause before and after the escape sequence is issued. The guard time

 

 

prevents the modem from interpreting data as the escape sequence

 

 

characters.

 

 

Enter a value from 0±255 in 20-millisecond increments. For example, the

 

 

factory setting of 50 equals 1000 milliseconds or one second.

 

 

Factory setting is 50 (1 second).

 

 

 

 

3980-A2-GB30-20

November 1996

13-15

Page 138
Image 138
Paradyne 3800PLUS manual 2 of 3800Plus S-Registers, AT Command, Description, Front Panel Branch, Line Feed Character